  • Page 1 ® - FLATSCAN SL recessed COMPACT LASER SCANNER FOR SLIDING DOOR User’s Guide for product version 0100 and higher See product label for serial number...
  • Page 2: Accessory (Optional)

    DESCRIPTION The LZR -FLATSCAN SL is a multi-functional sensor for automatic sliding doors based on laser ® recessed technology. It secures the door closing area and also offers a virtual push button for open the door. To do so, please must install the sensor in the canopy of the door. Sensor body Laser window protection Angle adjustment screw...
  • Page 3: Safety Tips

    SAFETY TIPS The device contains two visible laser beams that can be activated during the installation process to precisely adjust the position of the detection field. CLASS 1 LASER PRODUCT CLASS 1 LASER PRODUCT CLASS 2 LASER RADIATION Do not look directly into these red beams or laser emitters (Class 2). DURING INSTALLATION.
  • Page 4: Dip Switch

    INSTALLATION DIP SWITCH DIP 1 OUTPUT CONFIGURATION NO/NC NO/NO Switch to CRITICAL when external disturbances are DIP 2 ENVIRONMENT standard critical* likely to cause unwanted detections. Switch to OFF when there is no background DIP 3 BACKGROUND (e.g. glass floor). DIP 4 MONITORING active low active high...
  • Page 5: Push Buttons

    PUSH BUTTONS Quickly double click to activate or deactivate the visible laser spots. Press for 2 seconds to launch a safety field teach-in process. Press for 3 seconds to confirm the setting after changing the DIP switch. to acknowledge the 6x flashing error message and confirm that you want Press for 5 seconds the sensor to be mounted higher than 4m.
  • Page 6 DETECTION ZONE SETTING & TEACH-IN Set the detection range either automatically or with the remote control: Safety field teach-in To launch a teach-in, press 2 seconds the push button by remote control ( The sensor starts flashing red-green quickly and automatically learns the installation height. (Please make sure to stand outside the detection field before starting the teach-in process.) Wait until the sensor flashes green.
  • Page 7: Front Face

    FRONT FACE Clasp the front cover to finish the installation. Protect the laser window in case of construction works. PARAMETER SETTINGS WIDTH SAFETY (right) FIELD no field HEIGHT no field WIDTH (left) A new teach-in overwrites these values. no field PUSH BUTTON FIELD VPB1...
  • Page 8: How To Use The Remote Control

    UNCOVERED In order to change these settings by remote control, adjust DIP-switch 2 to ON. ZONE Uncovered zone: increase in case of snow, dead leaves, etc. *Measured in specific In case of false detection, button are not recommended. conditions and dependant on When DIP 2 is OFF, will change automatically to (10cm).
  • Page 9: Service Mode

    CHECKING A VALUE x = number of flashes = value of the parameter = field width: 2.35 m DETECTION FIELD ADJUSTMENT increase/decrease the detection field of 1cm. TEACH-IN Launch detection field Teach-in* Launch environment learning* Launch VPB Teach-in* * refer to the teach-in process on page 5. VISIBLE SPOTS turn on/ off the visible spots.
  • Page 10: Troubleshooting

    TROUBLESHOOTING In case of unwanted reactions of the door, verify whether the sensor or the controller causes the problem. To do so, activate the service mode (no safety) and launch a door cycle. If the door cycle is complete successfully, check the sensor.
  • Page 11 TROUBLESHOOTING The ORANGE LED is on The sensor encounters a Send the sensor back for a technical check-up. permanently. memory problem. The ORANGE LED flashes DIP-switch setting awaiting Corfirm the DIP-switch setting: long push on the quickly. confirmation. push button. The ORANGE LED flashes The sensor signals an Cut and restore power supply.
  • Page 12: Technical Specifications

    EN 61000-6-3:2007 + A1:2011 EN IEC 61000-6-2:2019 Specifications are subject to change without prior notice. All values are measured in specific conditions. BEA / A-B Area, 3rd Floor, No.1 Building No.5 Xinghai Road, Beijing Economic Technological Development Area, Beijing CHINA...