Auxiliary Controls; All Electric Heat; Cooling/Heating—Smart Fan - GE Zoneline AZ58H12DAD Owner's Manual And Installation Instructions

Heat pump model 5800
Hide thumbs Also See for Zoneline AZ58H12DAD:
Table of Contents

Advertisement

Available languages

Available languages

Auxiliary Controls on your Zoneline.
Auxiliary Controls – Dip Switches
The auxiliary dip switch controls are located
behind the room cabinet, through an opening
below the control panel.
Remove the room cabinet. See the To Remove the
Room Cabinet section.
The owner is responsible for checking switches
and ensuring they are in the desired position.
ALLI
C: FAN CN (Cooling–Smart Fan)
H: FAN CY (Heating–Smart Fan)
CLASS 2 (Remote Thermostat)
LOAD SHEDDING (CDC)
FREEZ Sen (Freeze Sentinel)
CONST FAN (Constant ON Fan)
OCCUPIED (Occupancy Sensor)

All Electric Heat

When this switch is enabled (UP), heat pump
operation is locked out, causing the unit to
provide only electric resistance heat.
Cooling–Smart Fan
When this switch is enabled (UP), it allows the
indoor fan to cycle on/off with the compressor.
When this switch is disabled (DOWN), it allows
the indoor fan to run continuously.
Heating–Smart Fan
When this switch is enabled (UP), it allows the
indoor fan to run continuously. When this
switch is disabled (DOWN), it allows the indoor
fan to cycle on/off with the heat pump or
heater operation.
2
R (All Electric Heat)
Reserved for future use
DIAGNOS (Diagnostic Check)
BOOST (Heat Boost Operation)
HEAT S (Heat Sentinel)
TL1 (H) (Temp. Limit 1–Heat)
TL2 (H) (Temp. Limit 2–Heat)
TL3 (H) (Temp. Limit 3–Heat)
TL1 (C) (Temp. Limit 1–Cool)
TL2 (C) (Temp. Limit 2–Cool)
TL3 (C) (Temp. Limit 3–Cool)
ALLI
2
R (All Electric Heat)
C: FAN CN (Cooling–Smart Fan)
H: FAN CY (Heating–Smart Fan)
ge.com
Dip Switches
5