MAKE ELECTRICAL CONNECTION TO THE UNIT
DIRECT CONNECTION
REMOVE JUNCTION BOX
1
1 Remove the junction box cover by taking out the
front four screws.
2 Remove the junction box by taking out the top rear
screw. Note how the tab on the lower right corner
of the junction box serves to hold the side in place.
This will help when the box is being reinstalled.
Junction
Junction
box cover
box
CONNECT THE CORDSET
2
Plug the connector, provided in the Direct Connect
Kit, fully into place in the unit mating connector.
Be sure the locking tabs at the sides are engaged.
Connector
NOTE: Order Kit RAK4002CW to enable a quick
disconnect inside the junction box.
Installation Instructions
Unit connector
Tab on
unit
Slot in
junction box
ATTACH CONDUIT
3
1 Use the round knockout at the bottom of the
junction box to attach conduit coming from the
branch circuit. Remove the knockout, attach the
conduit and bring wires into the junction box.
Leave 6" of wire free at the end of the conduit
to allow connections to be made.
2 If a fuse and fuseholder are to be used, the
knockout at the top of the box is for mounting
a Buss Fuseholder. Be sure the fuse and fuseholder
are of the same rating as the branch circuit.
Leadwires at the fuse can be either soldered in
place or attached using UL-listed 1/4" female
(receptacle) crimp connectors.
REINSTALL JUNCTION BOX
4
• Reinstall the junction box by engaging the tab at the
lower rear, aligning the screw hole at the top and
driving the one screw until secure. Be sure that all
wire leads are inside the box and not pinched
between the box and the unit. The green insulated
ground wire from the unit MUST be connected to
the branch circuit ground wire.
Make all wire connections by using appropriate
UL-listed electrical connectors and techniques
(black to black, white to white and green to green).
REINSTALL JUNCTION
5
BOX COVER
1 Carefully tuck all wires and
connections back inside the
junction box. Be sure there
are no loose connections or
stray uninsulated wires
exposed.
2 Place the junction box cover
in place. Replace the two
screws removed earlier and
tighten securely.
3 Discard the unused portion of the plug and
the cordset.