Specification
Type AWB/AWB-AC
Refrigerant circuit
Refrigerant
Filling capacity
Top-up amount for line
lengths >12 m to
≤30 m
Compressor (hermeti-
cally sealed)
Permiss. operating
pressure
■ High pressure side
■ Low pressure side
Dimensions
External unit
Total length
Total width
Total height
Internal unit
Total length
Total width
Total height
Total weight
External unit
Internal unit type AWB
Internal unit type AWB-
AC
Permiss. operating
pressure, secondary
side
128
(cont.)
201.B04
kg
g/m
Type
Rotating
bar
MPa
bar
MPa
mm
mm
mm
mm
mm
mm
kg
kg
kg
bar
MPa
201.B07
R410A
R410A
1.2
2.15
20
60
Rotating
piston
piston
43
43
4.3
4.3
43
43
4.3
4.3
869
1040
290
340
610
865
450
450
360
360
905
905
43
66
34
34
38
38
3
0.3
0.3
201.B10
R410A
2.95
60
Scroll
43
4.3
43
4.3
900
340
1255
450
360
905
110
37
42
3
3
0.3
201.B13
R410A
2.95
60
Scroll
43
4.3
43
4.3
900
340
1255
450
360
905
110
37
42
3
0.3