Siemens MKB-1 Operating Instructions Manual

Mxl multi-line keyboard/display panel
Hide thumbs Also See for MKB-1:

Advertisement

Quick Links

Operating Instructions
MXL Multi-Line Keyboard/Display Panel
Local Mode Operation
INTRODUCTION
THE DISPLAY
P/N 315-048692-2
When the MXL Keyboard/Display Panel is installed in a control panel, the compo-
nents are behind a locked door. Unlock and open the door to gain access to the keys
and controls.
The ¼ VGA display allows the user to view up to 8 lines of events and 1 complete
system status line at the same time. The ninth line of the screen is a fixed line that is
located below the 8 listed events that are visible, and holds the highest priority
unACKowledged event. What is shown on the display depends on the current state
of the System.
If your system is set for Canada, the
oldest event appears in the first line
of the display.
If your system is set for the United
States, the most recent event
appears in the first line of the
display.
Line 10 contains the system status
information which is grouped by
event type.
Lines 11 and 12 normally display the
System messages, date and time.
This area on the display functions
like the MKB-1/-2/-3/-4 two-line
display. Press ENTER to activate the
MXL menu options.
Lines 13, 14 and 15 are used to
display more information on a
particular event when the user
presses the MORE INFO key.
The System has several displays.
When the System is first powered
on it displays a screen similar to the
one shown in Figure 1.
1
2
3
4
5
6
7
8
9
10
11
SIEMENS FIRE SAFETY
12
APP : RX.X.X
13
14
15
Example shown is Canadian Display
Figure 1
MXL Keyboard/Display in Start-up Mode
Siemens Building T T T T T ec
Siemens Building
Siemens Building
Siemens Building
Siemens Building
ec
ec
hnologies
hnologies
ec
echnologies
hnologies
hnologies
Fire S
Fire S
afety
afety
Fire Safety
Fire S
Fire S
afety
afety

Advertisement

loading

Summary of Contents for Siemens MKB-1

  • Page 1 MXL Keyboard/Display in Start-up Mode When the System is first powered on it displays a screen similar to the one shown in Figure 1. Siemens Building Siemens Building Siemens Building T T T T T ec hnologies hnologies Siemens Building Siemens Building echnologies...
  • Page 2 All examples in this document are given for the Canadian display. When the system is in Normal mode, the display is similar to the one shown in Figure 2. ALR=000, SUP=000, TBL=000, SEC=000 SIEMENS BUILDING TECHNOLOGIES 12:22:22 Oct 22, 02 (000 / 000) Example shown is Canadian Display...
  • Page 3 OUT ACK Highest Priority Unacknowledged Event TBL BELL #1 (IAC 1) (main) System Status ALR=000, SUP=000, TBL=017, SEC=001 Line System Message SIEMENS BUILDING TECHNOLOGIES Current Time/Date 12:22:22 October 22, 02 Event Address Device Type 2-001 Audible Loop Queue Event #...
  • Page 4: Display Keys

    ALT 1 ALT 2 FUNCTION/ FUNCTION/ FUNCTION/ FONCTION FONCTION FONCTION HELP/ AIDE PRINT/ IMP. PQRS WXYZ SPACE/ ESPACE ENTER/ CLEAR/ ENTRER EFFACER Figure 4 The MKB Keyboard/Multi-Line Display Panel (Canadian Model is Shown Here) Siemens Building Technologies P/N 315-048692-2 Fire Safety...
  • Page 5 Siemens Building Technologies P/N 315-048692-2 Fire Safety...
  • Page 6 The display shows each number as you press the key (except when you enter a password the System shows an asterisk for each digit that you type). Siemens Building Technologies P/N 315-048692-2 Fire Safety...
  • Page 7 The PRINT key is used to print various lists and reports. To cancel the printing at any time, press the CLEAR key; the System will print the following message: This listing prematurely terminated. Siemens Building Technologies P/N 315-048692-2 Fire Safety...
  • Page 8 System’s internal audible to sound and the display on the MKB to display the event in the format shown in Figure 5. When the country setting is US, the AUDIBLE SILENCE LED flashes. Siemens Building Technologies P/N 315-048692-2 Fire Safety...
  • Page 9 40 Characters ALM CUSTOM MESSAGE ALM CUSTOM MESSAGE ALM CUSTOM MESSAGE ALR=002, SUP=000, TBL=000, SEC=000 SIEMENS BUILDING TECHNOLOGIES 12:01:01 Dec 31, 02 1-001 ID-60I Ionization Detector (002 / 002) 11:59:59 Dec 31, 02 Example shown is Canadian Display Figure 5...
  • Page 10 System, the internal audible goes silent; if any of those conditions still exist, the internal audible pulses. • If your System includes a printer, it prints a message similar to the following: ACK Alarm 12:05:44 Dec 31,20 All Alarms Are Now Acknowledged. Siemens Building Technologies P/N 315-048692-2 Fire Safety...
  • Page 11 AUD SIL alternately silences and unsilences the System.) If your System has a printer, it prints a message similar to the following: AUD. SILENCED/UNSIL. 11:01:00 Dec 31, 20 Audibles Silenced Siemens Building Technologies P/N 315-048692-2 Fire Safety...
  • Page 12 40 Characters SUP CUSTOM MESSAGE SUP CUSTOM MESSAGE SUP CUSTOM MESSAGE ALR=000, SUP=002, TBL=000, SEC=000 SIEMENS BUILDING TECHNOLOGIES 12:01:22 Dec 31, 02 1-001 (002 / 002) 11:59:59 Dec 31, 02 Example shown is Canadian Display...
  • Page 13 If your System includes a printer, it prints the following message: ACK Supervisory 11:59:59 Dec 31,20 All Supervisories Are Now Acknowledged. • If you press SUP ACK again, the System displays: ALL SUPERVISORIES ACKNOWLEDGED Siemens Building Technologies P/N 315-048692-2 Fire Safety...
  • Page 14 40 Characters TBL CUSTOM MESSAGE TBL CUSTOM MESSAGE TBL CUSTOM MESSAGE ALR=000, SUP=000, TBL=002, SEC=000 SIEMENS BUILDING TECHNOLOGIES 12:22:22 Dec 31, 02 1-001 FP-11 ASD Testing Enabled 11:59:59 Dec 31, 02 (002 / 002)
  • Page 15 Note the specific location of the trouble(s) by using the procedures de- scribed above. • Unlock and open the door. • Press TRBL ACK to acknowledge all troubles. The System displays the following message: ALL TROUBLES ACKNOWLEDGED Siemens Building Technologies P/N 315-048692-2 Fire Safety...
  • Page 16 40 Characters SEC CUSTOM MESSAGE SEC CUSTOM MESSAGE SEC CUSTOM MESSAGE ALR=000, SUP=000, TBL=000, SEC=002 SIEMENS BUILDING TECHNOLOGIES 12:22:22 Dec 31, 02 1-001 (002 / 002) 11:59:59 Dec 31, 02 Example shown is Canadian Display...
  • Page 17 The SECURITY LED glows steadily to indicate that all security conditions are acknowledged, and the internal audible goes silent. • If your System includes a printer, it prints the following message: ACK Security 12:05:44 DEC 31, 20 All Security Conditions Are Now Acknowledged. Siemens Building Technologies P/N 315-048692-2 Fire Safety...
  • Page 18 When the condition is corrected, the flashing icon will then disappear. 40 Characters TBL CUSTOM MESSAGE ALR=000, SUP=000, TBL=001, SEC=000 SIEMENS BUILDING TECHNOLOGIES 12:22:22 Dec 31, 02 Ground Fault Indicator 001 Ground Fault Plus...
  • Page 19 ALARMS NOT ALL ACKNOWLEDGED YET (or) SUPERVISORY NOT ALL ACKNOWLEDGED YET (or) TROUBLES NOT ALL ACKNOWLEDGED YET (or) SECURITY NOT ALL ACKNOWLEDGED YET (or) AUDIBLES NOT ALL SILENCED YET Siemens Building Technologies P/N 315-048692-2 Fire Safety...
  • Page 20 When reading "Using the Menu" in the above referenced manual, substitute DOWN for NEXT and UP for HOLD. The HOLD feature is not needed to freeze the screen when using the Multi-Line Display. Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road...

This manual is also suitable for:

Mkb-2Mkb-3Mkb-4Mxl