Preliminary adjustment of the needle height
.05.08
Requirement
When the needle bar is positioned at t.d.c. (balance wheel position 0°), the clearance
between the needle point and the needle plate should be 22 mm.
3
Fig. 1 - 08
●
Without turning it, re-position needle bar
requirement.
1
2
1
Make sure that needle bar 1 and foot 3 do not collide.
1 (screw 2) in accordance with the
Adjustment