Safety systems

Caution!
– Do not use any cleaning agents
containing alcohol or spirits.
– Do not use any sharp, pointed or metal
objects.
– Do not use abrasive cloths or cleaning
agents.
Notes:
– Clean all parts immediately after use.
This will prevent residues from drying
on and possibly attacking the plastic
(e.g. essential oils in herbs).
– When processing food such as
carrots, the plastic parts may become
discoloured, but this can be removed
with a few drops of cooking oil.
– To make cleaning the blender jug easier,
remove the cover from the handle and
replace once dry.
In Fig. F, you will find a summary of how to
clean the individual parts.
Safety systems
Start lock-out and
automatic cut-out
The appliance can only be operated
if the blender jug has been correctly
positioned and if the rotary selector is
turned to the zero setting when switching
on the appliance or after an interruption
in the power supply. The appliance will
switch off automatically if the blender jug
becomes detached while it is running.
The appliance automatically switches off
after 5½ minutes of continuous operation.
X "Troubleshooting" see page 16
Overload protection
The motor switches off automatically if the
appliance overheats. X "Troubleshooting"
see page 16
Note: When activating the overload
protection, a slightly strange smell may
occur. This is not a sign of malfunction.
16

Troubleshooting

W Risk of injury!
Before dealing with any faults, unplug the
mains plug.
Note: The appliance will no longer
switch on if there is an error in appliance
operation, if the electronic fuses trip or the
appliance has a defect. First try to eliminate
the problem which has occurred with the
help of the following information.
Caution!
If a fault cannot be eliminated, please
contact customer service.
Fault
Appliance fails to start up or switches off
while in use. The status display flashes.
Possible causes
– Blender jug is not correctly positioned,
has become detached or has been
removed.
– Rotary selector was not at the zero
setting when switching on or after an
interruption in power.
– The appliance was operating
continuously for longer than
5½ minutes.
Remedy
■ Switch off the appliance with the
开/关 (on/off) switch.
■ Position the blender jug correctly.
■ Turn the rotary selector in an
anticlockwise direction as far as it will go
(zero setting).
■ Switch on the appliance with the
开/关 (on/off) switch. The status display
lights up.
Fault
Appliance fails to start up or switches off
while in use.
Possible cause
The overload protection device is activated.
Remedy
■ Turn the rotary selector in an
anticlockwise direction as far as it will go
(zero setting).