Sony TRINITRON KV-AR25M90B Service Manual page 33

Hide thumbs Also See for TRINITRON KV-AR25M90B:
Table of Contents

Advertisement

KV-AR25M90B
RM-W104
V.LINEARITY (VLIN), S CORRECTION (SCOR), EW
PARABOLA/WIDTH (EWPW), AND EW TRAPEZIUM
(EWTZ) ADJUSTMENTS
1. Input Monoscope signal.
2. Activate the Service Mode.
3. Select VLIN, SCOR, EWPW, and EWTZ with
.
4
4. Adjust with
and
3
5. Press [MUTING] then
V LINEARITY (VLIN)
S CORRECTION (SCOR)
EW PARABOLA/WIDTH (EWPW)
EW TRAPEZIUM (EWTZ)
1
for the best Picture.
6
to save into the memory.
-
HORIZONTOL PARALLELOGRAM (HPAR), H BOW
(HBOW), UPPER PIN (UCOP) AND LOW PIN (LCOP)
ADJUSTMENTS
1. Input Monoscope signal.
2. Activate the Service Mode.
and
3. Select the HPAR, HBOW, UCOP, and LCOP with
and
.
4
4. Adjust with
3
5. Press [MUTING] then
HORIZONTOLPARALLELOGRAM (HPAR)
HORIZONTOL BOW (HBOW)
UPPER PIN (UCOP)
LOW PIN (LCOP)
– 32 –
and
for the best picture.
6
to save into the memory.
-