3.3 ADJUSTMENTS

3.3.1 POTENTIOMETERS

POT
NAME
RV1
BRAKING
TIME
RV2
TORQUE

3.3.2 LINK SELECTION

LINK
NAME
JP1
VOLTAGE
LEVEL
HI setting is only used when the stopping time is critical and must be around 1-2 seconds.
For this application 300% DC current is not adequate. Consult factory before using this
jumper position.
When the DC Injection unit is set on the HI level a current surge could occur due to the
motor CEMF and the free wheeling action of the power circuit.

3.3.3 PUSHBUTTON

PUSHBUTTON
SW1
RANGE
DEFAULT
SETTING
1-60 sec
30%
100-300%
50%
POSITION DESCRIPTION
LO
Braking action starts when motor starter has opened
(Normal)
and the motor terminal voltage has decreased to 30%
of the line voltage.
HI
Braking action starts when motor starter has opened
and the motor terminal voltage has decreased to 80%
of the line voltage. See important notes below.
NAME
DESCRIPTION
RESET
Reset IOC fault trip
PAGE 10
DESCRIPTION
Adjust the braking time
CW rotation increases the time
Adjust DC current
CW increases the braking torque
(current)