4.5.3 CHANGE AND MEMORY OF SETTING VALUE
SELECTION OF SETTING ITEM
• [FUNCTION
/ ] key.
For scrolling up / down the setting items.
• [FUNCTION
/ ] key.
For select the setting items.
CHANGE OF SETTING VALUE (DATA)
• [FUNCTION
/ ] key.
For scrolling up / down the setting values.
MEMORY OF SETTING VALUE (DATA)
The setting value will be stored automatically when release the
REMOTE CONTROL UNIT keys.
4.6
ADJUSTMENT PROCEDURE
4.6.1 VIDEO CIRCUIT
Measuring
Item
instrument
WHITE
Remote
BALANCE
control unit
Signal
generator
This service manual does not describe TROUBLESHOOTING.
Victor Company of Japan, Limited
Display Division 12, 3-chome, Moriya-cho, Kanagawa-ku, Yokohama-city, Kanagawa-prefecture, 221-8528, Japan
(No.YA693<Rev.001>)
Test point
Adjustment part
[White Balance]
Normal R
Normal G
Normal B
SECTION 5

TROUBLESHOOTING

4.5.4 FACTORY MODE SELECT KEY LOCATION
[Function / ] key
Scrolling up / down the
setting value.
[MUTING] key +
[INFORMATION] key
Enter The Factry Mode.
(1) Set COLOUR TEMP. to "Normal".
(2) Select "White Balance" from the FACTORY
MODE.
(3) Receive a PAL 75% all white signal.
(4) Adjust the setting values of <Normal R>,
<Normal G> and <Normal B> so that the
screen becomes maximum white.
NOTE:
When the normal mode is adjusted, other modes
(cool/ warm) are automatically adjusted.