Preliminary Examination; General Description - Hanna Instruments HI 2214 Instruction Manual

Ph/mv/c bench meter with custom buffers and interval logging
Table of Contents

Advertisement

EXTENSION CABLE FOR SCREW-TYPE ELECTRODES
(SCREW TO BNC ADAPTER)
HI 7855/1 Extension cable 1 m (3.3') long
HI 7855/3 Extension cable 3 m (9.9') long
OTHER ACCESSORIES
HI 710005
Voltage adapter from 115 VAC to 12 VDC (USA plug)
HI 710006
Voltage adapter from 230 VAC to 12 VDC
(European plug)
HI 710012
Voltage adapter from 240 VAC to 12 VDC (UK plug)
HI 710013
Voltage adapter from 230 VAC to 12 VDC
(South African plug)
HI 710014
Voltage adapter from 230 VAC to 12 VDC
(Australian plug)
HI 76404N Electrode holder
HI 8427
pH and ORP electrode simulator with 1 m (3.3') coaxial
cable ending in female BNC connectors
HI 931001
pH and ORP electrode simulator with LCD and 1 m (3.3')
coaxial cable ending in female BNC connectors
HI 7662
Temperature probe with 1 m (3.3') cable
HI 92000
Windows
®
compatible software
Windows
®
is registered Trademark of "Microsoft Co."
46

PRELIMINARY EXAMINATION

Remove the instrument from the packing material and examine it carefully
to make sure that no damage has occurred during shipping. If there is any
damage, notify your Dealer or the nearest Hanna Customer Service Center.
Each instrument is supplied with:
• HI 1131B Glass-body Combination pH Electrode with 1 m (3.3')
Cable
• HI 7662 Temperature Probe
• HI 76404N Electrode Holder
• pH 4.01 & 7.01 Buffer Solutions (20 mL each)
• HI 7082 Electrolyte Solution
• HI 700661 Electrolyte Solution
• 12VDC Power Adapter
• Instruction Manual
Note: Save all packing material until you are sure that the instrument
functions correctly. All defective items must be returned in the
original packing with the supplied accessories.

GENERAL DESCRIPTION

The HANNA HI 2214 and HI 2215 are microprocessor-based pH and
Temperature bench meters.
HI 2215 can also measure Oxidation Reduction Potential (ORP) in mV
range. Relative mV feature is also provided.
pH measurements are compensated for temperature effect manually or
automatically with the HI 7662 temperature probe.
Up to a five-point pH calibration can be performed using seven standard
buffers. In addition, two custom buffers can be used during calibration.
The GLP feature provides data consistency.
A calibration due alarm can be set to alert the user that too much time
elapsed since the last pH calibration.
Data can be stored in the meter's memory for later retrieval.
The meter's memory can hold 100 manually logged points and 500 lot
logging points (HI 2215 only).
A USB connection ensures communication with a PC.