OAL-100 INSTALLATION INSTRUCTIONS
WARNING!
READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY!
FAILURE TO DO SO MAY RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE!
AVOID ELECTRICAL SHOCK
DISCONNECT POWER DURING INSTALLATION
PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION
POWER SUPPLY REQUIRED 115+/- 5VAC-60 HZ 0.4 AMPS
CONTROL BOARD POWER SUPPLY 16VDC
CONTROL BOARD TO BE GROUNDED
KEEP FINGERS & CLOTHING CLEAR OF ALL MOVING PARTS
ADJUSTMENTS TO BE PERFORMED BY APPROVED TECHNICIAN ONLY
ALTERATION TO ANY COMPONENTS IS PROHIBITED
REMOVE ANY MECHANICAL DEVICES OR LOCKS THAT INTERFERE WITH THE
OPERATION OF THE DOOR, (OTHER THAN PARTS INTEGRATED WITH THE OPERATOR
SYSTEM)
OPERATOR TO BE INSTALLED 8 FEET MINIMUM ABOVE GROUND IF THERE ARE ANY
EXPOSED MOVING PARTS
1
OMEGA AUTOMATICS 2020 v3.0.2

Advertisement

Table of Contents
loading

Summary of Contents for Omega OAL-100

  • Page 1 OAL-100 INSTALLATION INSTRUCTIONS WARNING! READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY! FAILURE TO DO SO MAY RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE! AVOID ELECTRICAL SHOCK DISCONNECT POWER DURING INSTALLATION PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION POWER SUPPLY REQUIRED 115+/- 5VAC-60 HZ 0.4 AMPS...
  • Page 2: Table Of Contents

    4.3 Residual hazard ..............................8 5. Recommended tools ............................. 8 6. Standard torque ranges ............................8 7. OAL-100 installation process ..........................9 7.1 Unpack the box and take out cover ........................9 7.2 Installation of bottom track on the wall ......................9 7.3 Motor and control board wiring ........................
  • Page 3 10.1 Parameters ..............................20 11. Advanced setting .............................. 21 12. Terminal description ............................23 13. Parameter description ............................ 23 14. Re-Learn ................................24 15. Changes in software version ........................... 24 16. Programming encoder and parameters ......................25 OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 4: Installation Procedure

    Step 4 • Setup the magnets Step 5 • Connect the inputs/outputs to the control board Step 6 • Programming the system Step 7 • Close the header Step 8 • Place the AAADM Sticker Step 9 OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 5: Replacement Parts

    Swing door operator OAL-100 cover OA Ph-001 OAL-100 motor and Swing door operator OA Pm01 & OA Pg01 gearbox OAL-100 motor and HD Swing door operator OA Pm01 & OA Pg10 gearbox OAL-100 control board Swing door operator OA Pc01...
  • Page 6: General Information

    The OAL-100 is electromechanical operators used exclusively for opening and closing interior or exterior swing doors. The OAL-100 operator installed in a surface mount header at customer site. The header must be installed on an interior building surface. For double swing doors, both operators are installed in a single header.
  • Page 7: Hardware As Shipped

    Closer (LCN4040) 4. Safety information 4.1 Safety Instructions This document contains important instructions for installation of the OAL-100 swing door operators. Renew these instructions thoroughly prior to installation and follow them carefully during installation commissioning, troubleshooting and maintenance. 4.2 Safety warnings ❖...
  • Page 8: Residual Hazard

    8- Drill/ Drill bits 9- Torque wrench 10- Appropriate screws for application 11- Pressure gauge (0-35 lbf) Fig 5.1 6. Standard torque ranges Fastener size ft lb M5- #10 M6- 1/4 M8- 5/16 M10- 3/8 M12- 1/2 OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 9: Oal-100 Installation Process

    7. OAL-100 installation process 7.1 Unpack the box and take out cover ✓ Use 1/8" allen key to take out cover screws Fig 7.1.1 7.2 Installation of bottom track on the wall ✓ Mark the location of the motor on back plate ✓...
  • Page 10: Motor And Control Board Wiring

    ✓ Install control board on back plate using appropriate fasteners. Fig 7.2.4 7.3 Motor and control board wiring ✓ Connect motor wire to motor connector on controller. ✓ Connect limit switch wire to limit connector on controller. OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 11: Arm Installation

    ✓ If the power is not provided, use the arm to manually load the gearbox to hard stop by turning it until hard stop is reached. Lock the gearbox with metal rod through one of the 1/2” diameter holes at bottom of the gearbox. OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 12 ✓ Set the door to stay open at desired angle. ✓ Attach arm to spindle approx. 45° on door frame. Fasten 3/16 socket screw on arm ✓ Level the rod and attach the block on the arm to the door. OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 13: Pull Arm Application

    In the next step push the rod into gearbox (same as Fig 7.4.1.4) to stop it, then open the door to your desired fully open position and attach the pull arm to the spindle (Fig 7.4.2.1). In the last step, take out the rod and release the arm to reach the fully close position. OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 14: Programming (Basic)

    ✓ Slide the roller into the track and push the arm through the spindle then tight the screw with washer at the middle of spindle Fig 7.4.2.3 7.5 Programming (Basic) ✓ Setting door position switches. ✓ Refer to image how the top magnetic switches on gearbox should be set up OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 15 Fig 7.5.1 OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 16 ✓ Before accessing menu door needs to be fully closed and door operator control display should say door closed Door closed Fig 7.5.2 ✓ Press menu touch button Door closed Fig 7.5.3 ✓ Press SEL touch button to access parameters. Main Menu Fig 7.5.4 OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 17 ✓ Check the doorway for any obstacles and make sure that the door close and open smoothly. ✓ Check if the door is fully closed and display shows door closed press the ACT touch button. Door closed Fig 7.5.5 ✓ The display will show “door opening”. OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 18: Programming Heavy Duty (Xp) Operators

    ✓ Press MENU touch button then press down touch button to see “Calibrate”. Calibrate Fig 7.6.1 ✓ Then press the SEL touch button. ✓ Screen shows “Hit ACT to begin”. ✓ Press ACT button and manually push the door to the maximum opening position. OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 19: Trouble Shooting

    -Check the magnets and sensor wire -Check if the gearbox has tension -Check wiring -Check hardware Electric strike does not release -Check strike connection -Check strike voltage Touch buttons do not respond -Clean fingers or wipe the touch buttons OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 20: Universal Washroom Mode

    4. Signal from access control panel needs to be dry to connect device and signal from access control panel to proper terminals. 5. Once devices are wired and the door operator is programmed for basic setup, access advanced settings to change operating mode of controller. 10.1 Parameters ✓ Control mode: Change from 1 to 3 OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 21: Advanced Setting

    To access the advanced setting, the basic setting needs to be set and door operator should run its learning cycle. ✓ Press menu touch to access menu Main Menu [Settings] Fig 11.1 ✓ Press SEL to reach settings OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 22 Advanced setting are used for specific application of install such as access control universal washroom, motor revers on HD operator, opening or door exceeding 10 feet (adjustments and description of parameters can be found in parameters table). OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 23: Terminal Description

    Speed adjustment how fast will the door perform closing cycle Latch speed Speed adjustment how fast will the door perform latching cycle Ratcheting mode, holds the door on momentary trigger to act 1 Hold open terminal. Release the door on momentary trigger. (1_ON, 0_OFF) OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 24: Re-Learn

    Door operator will perform new learning. 15. Changes in software version V1.8- Standard Access control, washroom, motor revers V2.0- Safety Sensor Wiring diagram V2.3- Encoder, safety sensor, ACT DLY, preload time, preload speed, overload to 99 bypass. OMEGA AUTOMATICS 2020 v3.0.2...
  • Page 25: Programming Encoder And Parameters

    Pre-load time- time now long will the door operator reverse before opening to release pressure on strike (used only HD) Preload speed- Speed /force under which the door operator will reverse before opening to release pressure on strike (use only on HD) OMEGA AUTOMATICS 2020 v3.0.2...

Table of Contents