Owner Troubleshooting; Owner Troubleshooting Procedure; Fault Display Codes & Possible Owner Actions; [Flo] - Aquacal Aerotemp AT100 Owner's Manual

Pool and spa heat pump
Hide thumbs Also See for Aerotemp AT100:
Table of Contents

Advertisement

WARNING !
Heater contains no owner-repairable parts. Do NOT exceed the troubleshooting
actions explained below. If explained owner-troubleshooting fails to correct the
problem, do NOT attempt repairs to the heater...Contact your installing dealer or
AquaCal Customer Support: 1-800-786-7751.
Note...
This procedure is restricted to problems which may be related to the control system of your heater,
and/or site conditions affecting the ability of the control system to properly start and run your
heater. For other suspected problems, such as (but not limited to): "Heater Leaking Water",
"Heating, but Not Heating Enough", etc....Please refer to the heater Owner's Manual.
Insure correct water flow to the heater: Valves properly set, filter clean, and pump running;
1. Check heater power supply: All breakers and disconnect switches turned ON;
2. At this point, if no display is seen on heater control panel, call AquaCal Customer Support;
3. If display is now showing current water temperature, proceed with programming (Turn back
to Section Entitled: START UP & SETTING OPERATING CONTROLS.).
4. If display is NOT blank, but is NOT displaying current water temperature, but IS displaying
"Flo", re-verify correct water flow through unit. If water flow is correct, and "Flo" still
displays, contact AquaCal customer support.
Code
Error Description
[dPO]
Defrost Sensor Open
[PO]
Water Temperature
Sensor Open
[dPC]
Defrost sensor shorted
[PC]
Water temperature
sensor shorted
[LP]
Refrigerant system low
pressure switch open
[HP]
Refrigerant system high
pressure switch open

[FLO]

Low or no water flow
detected
[FS]
Heater in defrost mode

[CSE]

Control system error

OWNER TROUBLESHOOTING

Owner Troubleshooting Procedure:

Fault Display Codes & Possible Owner Actions
Contact installing dealer or Aquacal Customer Support
Contact installing dealer or Aquacal Customer Support
Contact installing dealer or Aquacal Customer Support
Contact installing dealer or Aquacal Customer Support
Contact installing dealer or Aquacal Customer Support
Contact installing dealer or Aquacal Customer Support
If correct flow has been determined per item #1 above- – Contact installing
dealer or Aquacal Customer Support
Normal function in lower air temperatures. Fan continues to run and
compressor is off. Compressor will restart when air coil temperature
reaches 38°F or above. If heater remains in defrost– Contact installing
dealer or Aquacal Customer Support
Controller may need to be reset. Disconnect then reconnect power to
heater; if error continues– Contact installing dealer or Aquacal Customer
Support
Failure to heed the following can result in
permanent injury or death.
Owner Actions
9