Advertisement

Quick Links

PAPERLESS RECORDER
Congratulations on your purchase of Fuji Paperless Recorder (Type: PHW)
• Read this instruction manual carefully to ensure correct installation, operation and preparation. Incorrect han-
dling may lead to accident or injury.
• Specifi cations of this unit is subject to change without prior notice for improvement.
• Modifi cation of this unit without permission is strictly prohibited.
Fuji will not be bear any responsibility for a trouble caused by such a modifi cation.
• This instruction manual should be kept by the person who is actually using the unit.
• After reading the manual, be sure to keep it at a place easy to access.
• This instruction manual should be delivered to the end user without fail.
Manufacturer
: Fuji Electric Co., Ltd.
Type
: Shown on nameplate of Recorder
Date of manufacture : Shown on nameplate of Recorder
Product nationality
: Japan
Related Information ........................................................ 1
Please Read First ........................................................... 2
For Proper Usage ........................................................... 5
1.
Installation ................................................................ 5
2.
Wiring....................................................................... 6
3.
Usage (Read before using) ...................................... 7
4.
Display and Operation Methods............................... 8
Confi rming Specifi cations
and Accessories
Before using the product, confi rm that it matches the
type ordered.
(For model code, please refer to page 12.)
Confi rm that all of the following accessories are in-
cluded.
Product name
(1)
Panel-mounting bracket
CD-ROM PC support software instruction manual
(2)
(both in Japanese and English)
(3)
Power supply noise filter
(4)
Quick reference (this manual)
Quick Reference
Type : PHW
INP-TN1PHWQRc-E
CONTENTS
Quantity
2
1
1
1
International Sales Div
Sales Group
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fujielectric.com
Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425
http://www.fujielectric.com/products/instruments/
Note: Windows is a registered trademark of Microsoft Corporation.
Modbus is a registered trademark of AEG Schneider Auto-
mation International.
Other product names are registered trademarks or trade-
marks of each manufacturer.
5.
List of Parameters .................................................... 9
6.
Troubleshooting ....................................................... 11
7.
Specifi cations ........................................................... 11
8.
Confi rming the Code Symbols ................................. 12
9.
Maintenance ............................................................ 12

Related Information

Refer to the following reference materials for details
about the items described in this manual.
Content
Specifications
Operation
Instruction Manual for
Method
Paperless Recorder (type: PHW)
Parameter
Parameter Loader Instruction Manual for
Loader
Paperless Recorder
(software)
Data Viewer
Data Viewer Instruction Manual for
(software)
Paperless Recorder
Communication Functions
Communication
Instruction Manual (Ethernet)
Function
for Paperless Recorder
- 1 -
Reference
Document
Number
Catalogue
ECNO: 1010
INP-TN1PHW-E
INP-TN513551-E
INP-TN513550-E
INP-TN5A0165-E

Advertisement

Table of Contents
loading

Summary of Contents for FE PHW

  • Page 1: Table Of Contents

    Type : PHW INP-TN1PHWQRc-E Congratulations on your purchase of Fuji Paperless Recorder (Type: PHW) • Read this instruction manual carefully to ensure correct installation, operation and preparation. Incorrect han- dling may lead to accident or injury. • Specifi cations of this unit is subject to change without prior notice for improvement.
  • Page 2: Please Read First

    • Never disassemble, remodel, modify, or repair this Please Read First instrument. Otherwise malfunction, electric shock, or failure may result. • Never touch the terminal while the instrument is be- ing energized. Otherwise electric shock or malfunc- Caution on Safety tion may result.
  • Page 3 • Mount the unit horizontally, with Caution no tilt to the left or right (The forward tilt should be 0° but the Cautions when installing unit may be inclined 0 to 30° ∠α rearwards). • Never use the instrument if it is found damaged or ∠α...
  • Page 4 (For example, inserting a wire etc. to the cooling is formatted, a display may appear on Windows slit on the product's main body.) indicating that formatting is completed, but PHW This equipment should be set on the metallic case does not recognize the completion of formatting.
  • Page 5: For Proper Usage

    For Proper Usage 1 Installation Dimensions/Panel Cutout <Details> <Reference Item> (unit : mm) • Please confirm that the model Dimensions Model Designation Confirmation Panel delivered matches your order. 220.5 • Dimensions Installation • Panel cutout • How to install on the panel •...
  • Page 6: Wiring

    2 Wiring Power supply terminal 100-240VAC?` M4 screw DO1 DO2 DO8 DO9 DO10 DO10 240V AC DO1-10 ?iRY?j 50/60Hz DO11 DO12 DO13 DO14 DO15 DO16 DO17 DO18 DO19 DO20 DO11 DO12 DO13 DO14 DO15 DO16 DO17 DO18 DO19 DO20 DO11-20 ?iRY?j Ethernet terminal DO21...
  • Page 7: Usage (Read Before Using)

    (3) Bar graph/analog meter display Be careful not to forcibly press the card if it is (4) Digital display inserted obliquely. Otherwise the pin on the PHW (5) Totalizing data display may be damaged. (6) Event summary display...
  • Page 8: Display And Operation Methods

    4 Displays and Operation Methods Data display screens Real time Bar gragh Digital Totalizing Event Ethernet trend operation display data summary (Group1) guide Analog meter (Group2) (Group2) (Group2) (Group3) (Group3) (Group3) (Group2) Historical trend (Group4) (Group4) (Group4) (Group2) (Group5) (Group5) (Group5) (Group3) (Group3)
  • Page 9: List Of Parameters

    5 List of Parameters ∗ Factory setting contents Copy Parameter names Setting range Remarks (initial value) setting Input Set Input type : K thermocouple Skip, K, E, J, T, R, S, B, N, W, L, U, Set the same PN thermocouple, Pt100, JPt100, 50mV, input types for every 2 500mV, 1 to 5V, 0 to 5V range,...
  • Page 10 ∗ Factory setting contents Copy Parameter names Setting range Remarks (initial value) setting Ethernet IP address : 192.168.1.1 0 to 255 (each digit) setting 1 Subnet mask : 255.255.255.0 0 to 255 (each digit) Default gateway : 0.0.0.0 0 to 255 (each digit) Ethernet FTP server function : OFF OFF, ON...
  • Page 11: Troubleshooting

    6 Troubleshooting 7 Specifications Error indications Specification Power voltage 100 to 240 V AC (±10%), 50/60 Hz This recorder is provided with an error display function. Power consumption (VA) : 80 VA max. (240 V AC) Modify the abnormal conditions as soon as an error Input measurement Range where input reading accuracy is assured.
  • Page 12: Confi Rming The Code Symbols

    8 Code Symbols 9 Maintenance 4 5 6 7 8 9 10111213 Recommended parts replacement cycle : 5 years (Due to degradation of Digit Specifications Note (Liquid crystal brightness of LCD back light, re- <Number of input points> display) turn to factory for repair.) Lithium battery : 5 years (pickup repair) Fuse (external) : 2 years (for preventive mainte- nance)

Table of Contents