Changing Point Number; Saving Point Data To File; Loading Point Data From File - Epson RC700 Manual

Robot controller option teach pendant
Hide thumbs Also See for RC700:
Table of Contents

Advertisement

Operation
2. TEACH Mode

2.1.15 Changing Point Number

Pushing <> and <▼> keys increases or decreases the point number by 1.
<> and <> keys increases or decreases the point number by 10.
To change the point number directly, execute <F10> point number.
(1) Press the <Shift> key.
(2) Press the <F10> key.
(3) Using the numeric keys and arrow keys, input a desired point number.
(4) Press the <OK> key.
TIP

2.1.16 Saving Point Data to File

You can save the point data registered in the memory to the point file.
(1) Press the <Save> key.
(2) Press the <OK> key to save the point data to the file.
TIP
This can also be executed in the [Point Editor] screen.

2.1.17 Loading Point Data from File

(1) Press the <Load> key.
(2) Move the cursor and select a file.
42
The mode turns to the point number input mode.
01 000 LJM T00A00
When you press the <Cancel> key, it returns to the [Jog &Teach] screen without
saving the change.
01 SavePoints
Robot1.PTS
01 LoadPoints
Robot1.PTS