Contents
APPROVALS ............................................................
FOREWORD ............................................................
INSTALLATION ........................................................
General ....................................................................
Location ...................................................................
Relief Devices ..........................................................
General ....................................................................
Branch Circuit ..........................................................
Recovery Rating
Standard
Models
KW Input
DRE/DVE
6
DRE/DVE
9
DRE/DVE
12
DRE/DVE
13.5
DRE/DVE
15
DRE/DVE
18
DRE/DVE
24
DRE/DVE
27
DRE/DVE
30
102,390
DRE/DVE
36
122,868
DRE/DVE
40.5
138,226
DRE/DVE
45
153,585
DRE/DVE
54
184,302
*Figured at 1 KW (3413 Btu) = 4.1 gallons at 100°F temperature rise.
To determine recovery rate per minute, divide recovery rate per hour by 60.
Approvals
Page
2
2
3
3
4
4
4
5
5
5
5
5
5-6
6
6
14
15
RECOVERY RATE IN GALLONS PER HOUR*
Temperature Rise °F
BTU/
Hour
30°
40°
20,478
82
62
30,717
123
92
40,956
164
123
46,075
184
138
111
51,195
205
154
123
61,434
246
184
148
81,912
328
246
197
92,151
369
276
221
410
307
246
492
369
295
554
418
3332
615
461
369
738
553
443
All models bear the
National Sanitation
Foundation seal of
approval.
Control Circuit .......................................................... 16-17
Power Circuit ............................................................ 18-21
General ....................................................................
Filling ........................................................................
Startup ......................................................................
Draining ....................................................................
General ....................................................................
Flushing ...................................................................
Checklist ..................................................................
50°
60°
70°
80°
49
41
35
31
74
62
53
46
98
82
70
61
92
79
69
102
88
77
123
105
92
164
140
123
184
158
138
205
176
154
246
211
184
277
237
208
307
263
230
369
316
277
All models are listed
by Underwriters
Laboratories Inc.
3
90°
100° 110°
120°
27
25
22
21
41
37
34
31
55
49
45
41
62
55
50
46
68
61
56
51
82
74
67
61
109
98
89
82
123
111
101
92
137
123
112
102
164
148
134
123
185
166
151
138
205
184
168
154
246
221
201
184
Page
16
16
22
22
22
22
22
22
23
23
23
24
24
25
26
130°
140°
19
18
28
26
38
35
43
40
47
44
57
53
76
70
85
79
95
88
113
105
128
119
142
132
170
158