ROTOR ASSEMBLY, STATOR ASSEMBLY, FRICTION DAMPER
1 Remove the back cover.
2 After loosening the bolt, Roto r , pull out the
rotor.
1 Remove the 6 bolts from the stato r.
2 Disconnect the 2 connectors.
Motor Stator
U V W
V ~ U (8~11 )
U ~ W (8~11 )
W ~ V (8~11 )
1 Remove the hinges (Damper) at the Tub.
2 The Hinge(Damper) at the base is pulled off by
pressing on the snaps at the sharp end.
3 The hinge at the base is pulled off.
(In directions of the arrow)
Hall Sensor
Hb
Common
Ha
Common ~ Ha (5~15k)
Common ~ Hb (5~15k)