Is the
Standpipe Height
greater
than 1.0 m above the floor?
NO
When there is no water in the
pump casing, is the water level
frequency over 26.0khz ?
YES
Is the
Connector
connected correctly to
the
Main PCB
and the
Pump Motor
Or is the
Harness
alright ?
YES
Is the resistance of the Pump Motor out
of range 152~175Ω?
Or is the Impeller operating normally?
Escape
OR
NO
Does the Pump motor start, when the spin mode
starts?
YES
If the drain hose blocked?
Observe
YES
of 1.0m maximum.
- Your washer will not be able to drain out
water adequately, if the standpipe exceeds 1.0 m.
In this case, water may flow back into the washer.
Check the
NO
Check the water level frequency again, if it is over
25.5KHz, replace the
switch.
Reconnect or repair the
NO
?
Or replace the
YES
Binding
NO
YES
Standpipe Height
requirements
Air Chamber
and the
Tube
If it is clogged, Pressure
Connector
.
Harness
.
Replace the
Pump Motor
.
Replace the
Main PCB
Clean the drain hose.