Sharp LC-42BX5H Service Manual page 18

Hide thumbs Also See for LC-42BX5H:
Table of Contents

Advertisement

LC-42BX5H/M/X
4.3. White balance adjustment
1. White balance adjustment procedure
Adjust the white 144 gradation using RGB CUTOFF2 and then the white 73 gradation with RGB-GAIN.
1) Test signal adjustment
[Input signal]
Display the WB test signals with built-in DVP of white 56% (144 gradations) and 29% (73 gradations) on the left and right of
the screen respectively by using the remote control code "011110010001010".
[Adjustment value]
Page 2 of adjustment process menu DVP hierarchy: RGB CUTOFF2, RGB-GAIN
White 56%
White 29%
[Adjustment method by bus]
Cutoff
RGB CUTOFF2
Gain
RGB-GAIN
5. MCL setting procedure
1. "MCL" is displayed in the upper left portion of the screen as shown in the figure below by sending the MCL key of the remote control for adjust-
ment.
MCL
2. When the screen disappears after a few seconds and appears again, MCL setting is complete.
Adjustment spec
±0.004
x = 0.261
±0.004
y = 0.277
±0.002
x = 0.261
±0.002
y = 0.277
G CUTOFF2 = Fixed to 0.
Vary RB CUTOFF2.
G-GAIN = Fixed to 0.
Vary RB-GAIN.
(The adjustment value is measured with MINOLTA CA-210 and the correction mode is measured in the
mode compatible with CH02 "TOPCON".)
5 – 5
Inspection spec
±0.01
Radius from the center point
±0.01
Radius from the center point
±0.01
Radius from the center point
±0.01
Radius from the center point
Adjustment range: ±30