Model (power
Connections to backup heater power
supply)
X6M
*6V (6V: 1N~ 230 V)
SWB2
F1B
32A
Q1DI
1N~, 50 Hz
230 V AC
X6M
*9W (3N~ 400 V)
SWB2
F1B
20A
Q1DI
3N~, 50 Hz
400 V AC
F1B 
Overcurrent fuse (field supply). Recommended fuse:
tripping class C.
Q1DI
Earth leakage circuit breaker (field supply)
SWB
Switch box
X6M
Terminal (field supply)
6.3.4
To connect the backup heater to the main
unit
Wires: The connection cables are already connected to the
option backup heater EKECBU*.
[9.3] Backup heater
1 Open the following (see
"4.2.1 To open the indoor
1 User interface panel
2 Switch box
3 Switch box cover
4 Top cover
2 Connect both connection cables from the backup heater
EKECBU* to the appropriate connectors as shown in the
illustration below.
ETSH/X(B)12P30+50EF
Daikin Altherma 3 H MT ECH₂O
4P663479-1 – 2021.07
supply
1
3
I
I
2
4
L
N
1
3
5
I
I
I
2
4
6
L1
L2
L3
N
unit" [ 4  7]):
3 Fix the cable with cable ties to the cable tie mountings. General
information, see
unit" [ 4  15].
indoor
6.3.5

To connect the shut-off valve

INFORMATION
Shut-off valve usage example. In case of one LWT zone,
and a combination of underfloor heating and heat pump
convectors, install a shut-off valve before the underfloor
heating to prevent condensation on the floor during cooling
operation. For more information, see the installer reference
guide.
Wires: 2×0.75 mm²
Maximum running current: 100 mA
230 V AC supplied by PCB
[2.D] Shut off valve
1 Open the following (see
1 User interface panel
2 Switch box
3 Switch box cover
4 Top cover
2 Connect the valve control cable to the appropriate terminals as
shown in the illustration below.
NOTICE
Wiring is different for a NC (normally closed) valve and a
NO (normally open) valve.
4