CONFIRMATION OF CHECK SUM, POWER ON TOTAL HOURS AND MICON VERSION
Initial total of MEMORY IC, POWER ON total hours and MICON VERSIONcan be checked on the screen. Total hours are
displayed in 16 system of notation.
NOTE:
If you set a factory initialization, the total hours is reset to "0".
Please refer to "CONFIRMATION OF INITIAL DATA" when SUM DATA is not corresponding.
1.
Turn on the POWER, and set to the ALL mode.
2.
Set the VOLUME to minimum.
3.
Press both VOL. DOWN button on the set and Channel button (8) on the remote control for more than 2 seconds.
4.
After the confirmation of each check sum, turn off the power.
NOTE:The each item value might be different according to each set.
Sub Micon check version
Main Micon check version
EEPROM check version
Parameter
CONFIRMATION OF INITIAL DATA
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken
to ensure correct data settings while making reference to INITIAL SETTING TABLE (Attached "INITIAL DATA").
1.
Turn on the POWER, and set to the ALL mode.
2.
Set the VOLUME to minimum.
3.
Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 2 seconds.
ADDRESS and DATA should appear as FIG 2.
NOTE: No need to set data other position than 7200~73FF.
4.
ADDRESS is now selected and should "blink". Using the UP/DOWN buton on the remote, step through the ADDRESS
until required ADDRESS to be changed is reached.
5.
Press LEFT/RIGHT button to select DATA. When DATA is selected, it will "blink".
6.
Again, step through the DATA using UP/DOWN button until required DATA value has been selected.
Pressing RIGHT/LEFT button will take you back to ADDRESS for further selection if necessary.
7.
Repeat steps 4 to 6 until all data has been checked.
8.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
9.
After the data input, set to the initializing of shipping.
10.
Turn on the Power.
11.
Set the VOLUME to minimum.
12.
Press both VOL. DOWN button on the set and Channel button (1) on the remote control for more than 2 seconds.
13.
After the finishing of the initializing of shipping, the unit will turn off automatically.
The unit will now have the correct DATA for the new MEMORY IC.
WHEN REPLACING EEPROM (MEMORY) IC
CHECK SUM: 40D3
LCD PWR ON: 0000
SUB:
DTV:
EEPROM: W50T01CM01
Picture: _dispSmartPic
INIT : 0001
SUB: DA0E77Y221
DTV: CA07E82071
EEPROM: W50T01CM01
DA0E77Y221
CA07E82071
FIG. 1
ADDRESS
DATA
0099
FIG. 2
C-4
Initial setting data check sum.
POWER ON total hours.
= (16 x 16 x 16 x thousands digit value)
+ (16 x 16 x hundreds digit value)
+ (16 x tens digit value)
+ (ones digit value)
22LV505

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

19lv50622lv505