AAON RN Series Installation Operation & Maintenance page 17

Packaged rooftop units, heat pumps, & outdoor air handling units
Table of Contents

Advertisement

RN A - 030 - C - 0 - 3 - C A B 0 A - 0 0 0
- 0 0 - 0 0 - 0 - 0 0 0 - 0 0 - B A 0 B - 0 0 - 0 0 0 - A 0 0 0 0 0 - C 0 0 0 0 0 - 0 0 0 0 0 0 B
B4: HEAT STAGING Continued
P = Single Serpentine 8 FPI
Q = Half Serpentine 8 FPI
R = Single Serpentine 10 FPI
S = Half Serpentine 10 FPI
T = Single Serpentine 12 FPI
U = Half Serpentine 12 FPI
B5: HEAT PUMP AUX HEATING
0 = No Heat Pump
A = Aux Heat 1 for Heat Pump 1 Stage
B = Aux Heat 2 for Heat Pump 1 Stage
C = Aux Heat 3 for Heat Pump 1 Stage
D = Aux Heat 4 for Heat Pump 1 Stage
E = Aux Heat 5 for Heat Pump 1 Stage
F = Aux Heat 6 for Heat Pump 1 Stage
G = Aux Heat 7 for Heat Pump 1 Stage
K = Aux Heat 1 for Heat Pump 2 Stage
L = Aux Heat 2 for Heat Pump 2 Stage
M = Aux Heat 3 for Heat Pump 2 Stage
N = Aux Heat 4 for Heat Pump 2 Stage
P = Aux Heat 5 for Heat Pump 2 Stage
Q = Aux Heat 6 for Heat Pump 2 Stage
R = Aux Heat 7 for Heat Pump 2 Stage
U = Aux Heat 1 for Heat Pump 4 Stage
V = Aux Heat 2 for Heat Pump 4 Stage
W = Aux Heat 3 for Heat Pump 4 Stage
Y = Aux Heat 4 for Heat Pump 4 Stage
Z = Aux Heat 5 for Heat Pump 4 Stage
1 = Aux Heat 6 for Heat Pump 4 Stage
2 = Aux Heat 7 for Heat Pump 4 Stage
1: UNIT ORIENTATION
0 = Standard Access - Hinged Access Doors with
Lockable Handles
A = Draw Through Compact Supply Fan, End
Compressor Compartment, Both Side Access
RN Series - Next Gen RN Feature String Nomenclature
0 0 : 0 1 - 0 A
G 0 K - E 0 0 - 0 0 0 0 0 - 0 0 0 0 0 - C A - 0 0 0 0
1: UNIT ORIENTATION Continued
B = Draw Through Compact Supply Fan, Walk-in
Vestibule with Left Vestibule Access, Both Side
Access
D = Draw Through Compact Supply Fan, Non-
Compressorized, End Control Panel, Both Side
Access
2: SUPPLY & RETURN LOCATIONS
0 = Bottom Supply--Bottom Return
A = Bottom Supply--No Return
V = Horizontal Configuration - End Supply--No
Return
Z = Horizontal Configuration - End Supply--Right
Return
1 = Horizontal Configuration - End Supply--End
Return
Feature 3: SUPPLY FAN OPTIONS
3A: SUPPLY FAN QUANTITY
0 = 1 Fan
A = 2 Fans
3B: SUPPLY FAN CONFIGURATION
0 = No VFDs + Full Width Fan
A = 1 Fan per VFD + Full Width Fan
B = 2 Fans per VFD + Full Width Fan
E = No VFDs + Narrow Width Fan
F = 1 Fan per VFD + Narrow Width Fan
G = 2 Fans per VFD + Narrow Width Fan
K = Option 0 + Inlet Backdraft Dampers
L = Option A + Inlet Backdraft Dampers
M = Option B + Inlet Backdraft Dampers
Q = Option E + Inlet Backdraft Dampers
R = Option F + Inlet Backdraft Dampers
S = Option G + Inlet Backdraft Dampers