Understanding command details

In this manual, commands and responses are expressed as follows.
20h 88h <ID1> <ID2> 0Ch <DATA01> - <DATA12> <CKS>
Command/response
Parameter
2.2

Parameters

The parameters that are used in the control commands are listed below.
Parameter name
ID1
ID2
CKS
LEN
DATA??
ERR1
ERR2
Example of checksum calculation
20h 81h 01h 60h 01h 00h <CKS>
①  Add all the data preceding the checksum.
"20h + 81h + 01h + 60h + 01h + 00h = 103h"
②  Use the low-order one byte "03h" of the addition result obtained in ① as the checksum.
©NEC Display Solutions, Ltd. 2014-2017
A series of strings enclosed in a frame represents a command or response (in
hexadecimal notation).
A character string in italic enclosed in brackets represents a parameter.
For information about the parameters that are common to the control commands
(ID1, ID2, CKS, LEN, ERR1, and ERR2), see "2.2 Parameters" (page 10). For
information about those parameters whose content varies from command to
command (DATA), see the description of the relevant command.
Control ID
The value of the "control ID" set for the projector is used.
Model code
This varies depending on the model in use.
Checksum
The checksum is calculated as follows.
Data length
This indicates the data length of the data part (DATA??) following LEN (in
bytes).
Variable length data
This varies depending on the character string stored.
Response error
The cause of an error is represented by a combination of error codes.
For information about error codes, see "2.4 Error code list" (page 12).
Description
① Add all preceding bytes of data.
② Use the value of the low-order one byte (eight bits) of the addition
result obtained in ① as the checksum.