*The dot of the BANK LED lights, then rotate to the next click.
*After the left end click was finished, the check proceeds to the next step.
2. DELAY SELECT knob (initial display BANK LED "C2")
Do the check same as the MODULATION SELECT knob. After finished, the check proceeds to the next
step.
3. REVERB SELECT knob (initial display BANK LED "C3")
Do the check same as the MODULATION SELECT knob. After finished, the check proceeds to the next
step.
Notice: *Pushing the INSERT switch, push WRITE and EXIT to move to the next step.
3. REVERB SELECT つまみ (初期表示は BANK LED "C3")
Operation Check 6. Volume A/D "VOL KNOB"(LCD)
1. Rotate the GAIN knob to the MAX (right end), confirm that the dot of the BANK LED lights.
2. Rotate the GAIN knob to the MIN (left end).
3. Same as 1 and 2, do following check of all knobs.
Knob
1. FX VALUE 1 (GAIN)
2. FX VALUE 2 (VR GAIN)
3. FX VALUE 3 (TREBLE)
4. FX VALUE 4 (MIDDLE)
5. FX VALUE 5 (BASS)
6. FX VALUE 6 (CH VOLUME)
Notice: Pushing the INSERT switch, push WRITE, EXIT to move the step.
Operation Check 7. Pedal calibration "PEDAL"(LCD)
1. EXP pedal calibration
1.1 Set the EXP PEDAL to the Mini side and push GLOBAL.
1.2 Set the EXP PEDAL to the Max side, confirm [-] in the LED.
1.3 Set the EXP PEDAL to the Mini side, confirm [=] in the LED.
1.4 Move the EXP PEDAL for several times and confirm that the display is [127] at the Mini,
[0] at the Max, and an error does not occur.
1.5 Push GLOBAL.
Operation Check 8. LCD all segments ON (LCD)
1. Confirm that all segments of the LCD turned ON, then push GLOBAL.
2. Confirm that all segments of the LCD turned OFF, then push GLOBAL.
3. Confirm that all segments of the LCD are blinking, then push GLOBAL.
Operation Check 9. Adjusting of the output of the vacuum tube, and
1. Waiting for heat-running of the vacuum tube
Wait for one minute from the power on, after one minute the check starts.
BANK LED
A1
A2
A3
A4
A5
A6
symmetricness check