Applying power to the machine with the plug fitted in the wrong position WILL CAUSE
PERMANENT DAMAGE to the module.
4. Lift module clear.
5. When replacing the board an EEProm will also be required.
Service modules are not normally supplied with a programmed EEProm.
Note: To remove and fit the EEProm use Insulated Tweezers Part No. C00066292 as shown
below.
On the original control board, the EEProm may be soldered to the board and cannot be
removed.
IC Removal Tool
EEPROM Removal from PCB
41
White Multiway
Connector Plug
Wires must exit the
plug as shown here
Ensure correct
orientation when
refitting