according to Panel option data.
1) Enter the service mode.
2) Select menu of ID by pressing P
service mode.
3) Change ID data into MODEL ID to initialize by pressing
below.
4) Press and hold the CALL button on the remote control, then press the CHANNEL
button on the TV.
5) Initialization progress dialog including model name and panel vendor is shown.
Progress status is "WRITING".
6) Progress status is changed "OK" and power cycle (automatically). Then QA02
initialization has been completed.
7) Enter the service mode and select version check mode. Confirm if model name and
model id set is correct. If not, repeat steps 1) to 6).
Note:
In case initialization by setting wrong MODEL ID is done, there is a possibility of
abnormal display.
8) Set I2C check function of TVOP to enable.
9) Check the picture carefully. If necessary, adjust any adjustment item above.
Perform "Auto tune" on the owner's manual.
MODEL ID (HEX) Model name Panel vendor
0x01
32AV505D
0x02
37AV505D
0x03
42AV505D
0x04
42AV505D
or P
during display of adjustment menu in the
IPS
IPS
LPL
AUO
+ or
-, refer to table