Download Print this page

Installing The Registers, Ductwork And Hoods - Broan ERVS100S Installation And User Manual

Hide thumbs Also See for ERVS100S:

Advertisement

Available languages

Available languages

3 Installation

3.3 Installing the Registers, Ductwork and Hoods

3.3.1 Registers
Never install a stale air exhaust register in a closed room where a combustion device operates, such as a gas
furnace, a gas water heater or a fireplace.
Refer to applicable building codes to plan where the stale air exhaust registers and fresh air distribution registers should be
installed. Below are some general recommendations.
Stale air exhaust registers:
• Install the stale air exhaust registers where the contaminants are produced: bathroom (up to 2), kitchen, living room, etc.
Position the registers as far from the stairway as possible and in such a way that the air circulates in all the lived-in spaces in
the house.
• If a register is installed in the kitchen, it must be located at least 4 feet away from the cooking applicances.
• Install the registers on an interior wall, 6 to 12 inches below the ceiling OR in the ceiling.
Fresh air distribution registers (Option 2 in 3.2.1):
• Install the fresh air distribution registers in bedrooms, dining rooms, living rooms and basement, if applicable.
• Keep in mind that the fresh air registers must be located as far as possible from the ERV stale air registers.
• Install the registers on an interior wall, 6 to 12 inches below the ceiling OR in the ceiling.
• If a register must be floor installed, direct the airflow up the wall.
3.3.2 Ductwork
When performing duct connections, always use approved tools and materials. Respect all corresponding laws
and safety regulations. Please refer to your local building code.
If ducts have to go through an unconditioned space (e.g.: attic), always use insulated ducts.
• All units ports should be connected to 6" ducts, but can be connected to larger ducts using an appropriate transition.
• If you have to connect rigid ducts to the unit, use a short lenght (approximately 6") of flexible duct to avoid transmission of
vibrations. Use a tie wrap and foil tape to connect the flexible duct to the port and to the rigid duct.
• Never use screws to connect rigid ducting to the ports.
Connecting insulated flexible ducts to the ports:
1. Pull back the insulation to expose the flexible duct.
2. Attach the flexible duct to the port using a tie wrap; ensure tie wrap is tighten to its maximum strength.
3. Pull the insulation over the joint, then pull the vapor barrier (shaded part in illustrations below) over the insulation. Make sure
that the vapor barrier does not tear due to manipulation to avoid condensation within the ducts.
4. Apply foil tape to the joint, making an airtight seal. Avoid compressing the insulation when pulling the tape tightly around the
joint. Compressed insulation loses its R value and causes water dripping in cold climates due to condensation on the exterior
surface of the duct.
NOTE: If sealant mastic has to be used over the foil tape as an extra sealing layer, use water based mastic to ensure material
compatibility with the port.
VJ0134
(cont'd)
T
IGHTEN TIE WRAP TO ITS
MAXIMUM STRENGTH
!
WARNING
!
WARNING
CAUTION
!
8

Advertisement

Chapters

loading

This manual is also suitable for:

Ervs100