Install Anti-Tip Bracket; Make Gas Connection - Whirlpool WGG745S0FS Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Install Anti-Tip Bracket

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Remove the anti-tip bracket that is taped inside the upper
oven with the package containing literature.
2. Determine which mounting method to use: floor or wall.
If you have a stone or masonry floor, you can use the wall
mounting method.
3. Determine and mark edge of range in the cutout space. The
mounting bracket can be installed on either the left side or
right side of the cutout. Position mounting bracket in cutout
so that right (or left) edge of the bracket is 15/16" (2.4 cm)
from the marked edge of the range, as shown.
B
A. Anti-tip bracket
B. Mark edge of range.
C.
8
8
A
C
" (2.4 cm)
15
16
4. Drill two 1/8" (3.0 mm) holes that correspond to the bracket
holes of the determined mounting method. See the following
illustrations.
Floor Mounting
A
B
A. #12 x 1
" screws
⁵⁄₈
B. Anti-tip bracket
5. Using a Phillips screwdriver, mount anti-tip bracket to the
wall or floor with the two #12 x 1

Make Gas Connection

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical flexible connection
1. Apply pipe-joint compound made for use with propane gas
to the smaller thread ends of the flexible connector adapters
(see B and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both
adapters, being certain not to move or turn the gas pressure
regulator.
Wall Mounting
A
B
A. #12 x 1
" screws
⁵⁄₈
B. Anti-tip bracket
" screws provided.
5
8

Advertisement

Table of Contents
loading

Table of Contents