5.2
Inserting the battery
CAUTION
Risk of injury! Inadvertent starting of the rotary hammer drill.
▶ Before installing the battery, check that the rotary hammer drill is switched off and that the forward/reverse
switch is in the middle position (i.e. switch-on interlock engaged).
1. Push the battery into the battery holder until it engages with an audible click.
2. Check that the battery is seated securely.
5.3
Removing the battery
1. Press the release buttons on the battery.
2. Pull the battery out toward the rear.
5.4
Fitting the side handle
CAUTION
Risk of injury! Loss of control over the product.
▶ Check that the side handle is fitted correctly and tightened securely. Check that the clamping band is
engaged in the groove in the product.
1. Release the side handle clamping band by turning the handle grip.
2. From the front, slide the depth gauge into the 2 guide holes.
3. Tighten the side handle clamping band by turning the handle grip.
5.5
Fitting and adjusting the depth gauge
▶ Fit the depth gauge, if necessary, and adjust it correctly.
5.6
Fitting / removing the chuck
CAUTION
Risk of injury! The depth gauge, if fitted but not used, might hinder the operator.
▶ Remove the depth gauge from the tool.
▶ Fit / remove the chuck.
5.7
Inserting accessory tool
1. Lightly grease the connection end of the accessory tool.
▶ Use only genuine Hilti grease. Using the wrong grease can result in damage to the tool.
2. Push the accessory tool into the chuck as far as it will go (until it engages).