8. Alignments

Index of this chapter:
8.1 Electrical Instructions
8.2 Serial Number Definition
Note: . The Service Mode are describe in chapter 5.Menu
navigation is done with the CURSOR UP, DOWN, LEFT or
RIGHT keys of the remote control transmitter.
8.1
Electrical Instructions
8.1.1
AV-1(YpbPr) mode Display adjustment
White balance adjustment (B)
19MF338B&19MD358B
General set-up:
Equipment Requirements: Quantum Data Pattern Generator or
Chroma2229/MTTK8256A Apply 1080i,SMPTE color pattern.
Pattern 27.
Figure 8-1 Pattern 27
Table 8-2 CLR_TEMP ADJUSTMENT
Panel ID:89
For S/W
Normal
CLR_TEMP R 0
CLR_TEMP G 0
CLR_TEMP B 0
Warm
CLR_TEMP R 0
CLR_TEMP G -5
CLR_TEMP B -16
Cool
CLR_TEMP R -1
CLR_TEMP G 11
CLR_TEMP B 44
1. Check the gray pattern should be distinguished and color
bar is correct.
Check Luminance Note:
Use Minolta CA-210 for colour coordinates and luminance
check.
Table 8-3 Reading with Minolta CA-210.
Normal
CCT
9300K
x
0.283 ± 0.015
y
0.297 ± 0.015
2.Check the gray pattern should be distinguished and color bar
is correct.
Check Luminance Note:
I_17550_012.eps
130208
YPbPr
ATV
0
-6
-8
0
-11
-25
0
8
40
Cool
Warm
11500K
6500K
0.273± 0.015
0.314± 0.015
0.280± 0.015
0.324± 0.015
Alignments
TPM1.1U LA
Inital Set-up:Set Smart picure
as"Personal",Brightness=50,Color=50,Contrast=50.Then run
factory "AUTO-COLOR" proces.
Alignment method:
Initial Set-up:Set Smart picture
as"Personal"(Brightness=50,Color=50,Contrast=50) and
check Factory "SP_MODE_PWM" for Personal/sports/
Standard/Movie=20 Power Saver=100.
Alignment:Adjust the factory "CLR_TEMP_R/CLR_TEMP_G/
CLR_TEMP_B" to meet NORMAL color temperature
requirement and check COOL WARM of color temp.
[Enter factory key 062596 by remoted number key then press
Info key]
Output Detection Points:Screen center.
Table 8-1 Check (X,Y) coordinates as belows
Normal/
(7500K)
x(center)
0.300 ± 0.005
y(center)
0.310 ± 0.005
Y(center)
200±20
If out of specification then fine-tune factory "CLR_TEMP_R/
CLR_TEMP_G/CLR_TEMP_B" for Normal temperature.Other
modes pls. refer to below form (for reference).
Remark:a,b,c,d are offset refer to Normal dada and build in
firmware to close warm x=0.314, y=0.324
and Cool x=0.285,y=0.293 as posible.If out of x,y in warm/cool
define tolerance 0.015 then fine-tune the offset value is
needed.
DTV
CVBS/S-Video HDMI
0
0
-6
-6
-9
-5
0
0
-11
-11
-25
-21
0
0
8
8
37
40
Use Minolta CA-210 for colour coordinates and luminance
check.
Luminance typical 300 Nits , Min. > 230 Nits
In the center of the screen when 'Smart picture' at
'PERSONAL',and Brightness and Contrast control set at 100%.
19PFL3403D
Equipment Requirements:Minolta CA-110 or CA-210 or
Equivalent Color analyzer.Quantum Data Pattern Generator
802G, 802BT, 881 or equivalent instrument.
Input requirements:
Input Signal Type : YPbPr signal
1. 1080i mode, TVBar100 pattern by 802G or 802BT or 881.
2. Select Smart picture to Personal mode and check the x, y
data.
Input Signal Strength : 1000mVpp for Y signal ; +/-350mV for
Pb & Pr signal
8.
Cool(9300K)
Warm(6500K)
X'= x± a
x'=x± c
Y'=y± b
y'=± d
PC(VGA)
0
0
-5
-6
-7
-11
0
0
-11
-12
-24
-31
0
-1
7
6
36
44
EN 51