Electrical Grounding Instructions; Hood Exhaust Duct; Tools Recommended For Installation - Sharp Carousel R1881LSY Installation Instructions Manual

Hide thumbs Also See for Carousel R1881LSY:
Table of Contents

Advertisement

3 ELECTRICAL GROUNDING INSTRUCTIONS

This appliance must be grounded. This oven is equipped with a cord having a grounding wire with a grounding plug. It must be
plugged into a wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local
codes and ordinances. In the event of an electrical short circuit, grounding reduces risk of electric shock by providing an escape
wire for the electric current.
WARNING - Improper use of the grounding plug can result in a risk of electric shock.
The oven is equipped with a 3-prong grounding plug. DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE
GROUNDING PIN FROM THE PLUG.
The Power Supply Cord and plug must be connected to a separate 120 Volt AC,
60 Hz, 15 Amp, or more branch circuit, single grounded receptacle. The recep-
tacle should be located inside the cabinet directly above the Microwave Oven/
Hood mounting location.
NOTE:
1. If you have any questions about the grounding or electrical instructions, consult
a qualified electrician or serviceperson.
2. Neither Sharp nor the dealer can accept any liability for damage to the oven
or personal injury resulting from failure to observe the correct electrical con-
nection procedures.

4 HOOD EXHAUST DUCT

When the hood is vented to the outside, a hood exhaust duct is required. All ductwork must be metal; absolutely do not use
plastic duct. Check that all connections are made securely. Please read the following carefully:
Exhaust connection: The hood exhaust has been designed to connect to a standard 31/4" x 10" rectangular duct. If round duct
is required, a rectangular-to-round adapter must be used.
Rear exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align the exhaust with the space between
the studs, or wall should be prepared at the time it is constructed by leaving enough space between wall studs to accommodate
exhaust.
Maximum duct length: For satisfactory air movement, the total duct
length of 31/4" X 10" rectangular or 6" diameter round duct should
not exceed 140 feet.
Elbows, adapters, wall, roof caps, etc. present additional resistance to
air flow and are equivalent to a section of straight duct which is longer
than their actual physical size. When calculating the total length, add
the equivalent lengths of all transitions and adapters plus the length
of all straight duct sections. Figure 4 shows the approximate feet of
equivalent length of some typical ductwork parts. Use the values
in parentheses for calculating air flow resistance equivalent, which
should total less than 140 feet.

5 TOOLS RECOMMENDED FOR INSTALLATION

• Phillips Screwdriver
• Electric Drill
• Scissors
• Pencil
• Tape
• Measure
• 1/2", 5/8" and 3/32" Drill Bits
• 1-1/2" Wood Bit or Metal Hole Cutter (if metal cabinet is used)
• Saw to cut exhaust opening (if needed)
• Protective Drop Cloth for product and range - you may also use carton for protection
2
Grounded
Receptacle
Opening for
Power Cord
Figure 3
Figure 4

Advertisement

Table of Contents
loading

Table of Contents