■Indicators and buttons
A
INITIAL SET button
(Initializing button)
SD slot cover
A
INITIAL SET button (Initializing button)
Follow the steps below to initialize the network camera.
Turn off the power of the camera. When using a PoE hub, disconnect the Ethernet cable from
the camera. When using an external power supply, disconnect the 2P power cable (accessory)
from the 12 V DC power supply terminal.
Turn on the power of the camera while pressing the INITIAL SET button, and make sure to
release the button after approximately 15 seconds. In about 2 minutes later, the camera will
start up and the settings including the network settings will be initialized. Retry if the camera
does not start up normally.
IMPORTANT:
⿟ When the camera is initialized, the settings including the network settings will be initialized.
Before initializing the settings, it is recommended to write down the settings in advance.
⿟ Do not turn off the power of the camera during the process of initialization. Otherwise, it may
fail to initialize and may cause malfunction.
<Inside view of the SD memory card slot cover
SD memory
card slot
B
* This illustration represents WV-S4550L
(with SD memory card slot cover opened)>
ACT indicator
LINK indicator
C
DSD ERROR/ABF indicator
SD ERROR indicator
G
SD memory card warning/error indicator
Dome cover
*Do not directly touch the dome cover
surface with your hands.
19
F
SD ON/OFF button
E
SD MOUNT indicator
X4571L
X4571LM
S4550L
S4550LM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wv-x4571lmWv-s4550lWv-s4550lm

Table of Contents