Panasonic WV-X4571L Important Information Manual page 16

Hide thumbs Also See for WV-X4571L:
Table of Contents

Advertisement

B
12 V DC power supply terminal / 2P power cable (accessory)
Caution:
⿟ A READILY ACCESSIBLE DISCONNECT DEVICE SHALL BE INCORPORATED TO THE
EQUIPMENT POWERED BY 12 V DC POWER SUPPLY.
⿟ ONLY CONNECT 12 V DC CLASS 2 POWER SUPPLY (UL 1310/CSA 223) or LIMITED
POWER SOURCE (IEC/EN/UL/CSA 60950-1).
Connect the output cable of the DC power supply to the 2P power cable (accessory).
IMPORTANT:
⿟ Be sure to use the 2P power cable (accessory) provided with this product.
⿟ Be sure to fully insert the 2P power cable (accessory) into the 12 V DC power supply
terminal. Otherwise, it may damage the camera or cause malfunction.
⿟ When installing the camera, make sure that excessive force is not applied to the power cable.
⿟ Be sure to use an AC adaptor compliant with the specifications (written in the indication label
on the bottom side of this unit) regarding power source and power consumption.
C
Alarm input/output cable / 4P alarm cable (accessory)
Connect the 4P alarm cable (accessory) to the alarm input/output cable, and connect the external
device cable to the 4P alarm cable.
Note:
⿟ Off, input, and output of the external I/O terminal 2 and 3 can be switched by configuring the
setting. Refer to the Operating Instructions on the provided CD-ROM for further information
about the EXT I/O terminal 2 and 3 (ALARM IN2, 3) settings ("Off", "Alarm input", "Alarm output"
or "AUX output").
<Ratings>
⿟ ALARM IN1 (Black & white input / Auto time adjustment input), ALARM IN2, ALARM IN3
Input specification : No-voltage make contact input (4 V - 5 V DC, internally pulled up)
OFF
ON
⿟ ALARM OUT, AUX OUT
Output specification : Open collector output (maximum applied voltage: 20 V DC)
ON
OFF
4P alarm cable
GND (Black)
ALARM IN3 (Alarm input 3/ AUX output) (Gray)
ALARM IN2 (Alarm input 2/ Alarm output) (Red)
ALARM IN1
(Alarm input 1/ Black & white input/ Auto time adjustment input) (Green)
IMPORTANT:
⿟ Install external devices so that they do not exceed the rating of the network camera.
⿟ When using the EXT I/O terminals as the output terminals, ensure they do not cause signal
collision with external signals.
: Open or 4 V - 5 V DC
: Make contact with GND (required drive current: 1 mA or more)
: 4 V - 5 V DC by internal pull-up
: Output voltage 1 V DC or less (maximum drive current: 50 mA)