Download Print this page

Troubleshooting - Philips DVP3111 Service Manual

Hide thumbs Also See for DVP3111:

Advertisement

All manuals and user guides at all-guides.com
Spindle motor does not move
Motor not move
Go
Check the FFC connection
between 24P and the loader.
Yes
Check whether "MO_VCC"
(VCC) voltage is normal.
Yes
Check whether laser voltage
(1.9V for CD & 2.3V for DVD)
on L21 & L22
Yes
1. Whether voltage on pin 23 of U2
varies between 0 and 3.3V (3.3V
for CD and 0V for DVD),
2. Whether peripheral components
are eroded or badly soldered.
Yes
Check opu focus
Yes
Check/Replace the loader
5-1
No
Correct connection
No
No
No
1. Check U2 25pin FOO signals
No
2.If there are F+, F-, T+ and T-
signals output from U1.
Trouble shooting chart
Check the MOVCC power
supply
Check/Replace Q10 Q11.
Check/ Replace U1.

Advertisement

loading