Commissioning

System components:
230 V AC Mains voltage
BUS
BUS system EMS 2/EMS plus
CON
Control unit EMS 2/EMS plus
HC1...
Heating circuits
HS
Heat Source
MC1
External swimming pool control unit (optional); if
there is no swimming pool control unit, connect
jumper to terminal MC1 ( Fig. 1 [2] at end of
document)
MP 100 Module MP 100
TC1
Swimming pool temperature sensor
VC1
Mixing valve motor
4
Commissioning
First make all electrical connections and then carry out the
commissioning!
▶ Observe the installation instructions for all components
and assemblies in the system.
▶ Only switch on the power supply after all modules are set
up.
1. If necessary, set the coding switch on other modules. The
coding switch on the module MP 100 has no function.
2. Connect the entire system to the mains voltage.
Once the status indicator on the module lights up green
constantly:
3. Put the control unit into operation as described in the
accompanying installation instructions and make the
appropriate settings.
14
5

Troubleshooting

Use only original spare parts. Damage caused by the use of
spare parts not supplied by the manufacturer is excluded from
the warranty.
▶ If a fault cannot be rectified, please contact your local
service engineer.
The On/Off indicator indicates the operating condition of the
module.
Some faults are also shown on the heat pump display.
Indicator
Possible cause Remedy
Constantly
Power supply
OFF
interrupted.
Faulty fuse
Short-circuit in
the BUS
connection
Constantly
Internal fault
red
Flashing
Maximum cable
green
length of BUS
connection
exceeded
 Fault display
on the control
unit display
Constantly
No fault
green
Table 8
4 5 6
3
7
2
8
1
9
10
0
▶ Turn on the mains
power supply.
▶ When the power supply
is switched off, replace
the fuse ( Fig. 13 at
end of this document).
▶ Check BUS connection
and repair if necessary.
▶ Replace the module.
▶ Shorten the BUS
connection.
▶ The corresponding
instructions for the
control unit and the
service manual contain
additional notices for
troubleshooting.