Junction Box Location; Gas Supply Installation - Frigidaire Professional FPDF4085KF Install Manual

40’’ dualfuel range
Hide thumbs Also See for Professional FPDF4085KF:
Table of Contents

Advertisement

Available languages

Available languages

40" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS

Junction Box Location

Locate junction box as shown in Figure 7.
If a service cord is used, the wall receptacle should be
located in accordance with the dimensions below.
Center
Line of
Range
20"
(50.8 cm)
10"
(25.4 cm)
7" Max.
(17.8 cm Max.)
Locate Electrical Hook-up
Inside Shaded Area
Figure 7
Range Placement
To eliminate the risk of burns or fire by
reaching over heated surface units, cabinet storage space
located above the range should be avoided. If cabinet
storage space is to be provided, the risk can be reduced
by installing a range hood that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom of the
cabinet.
Follow instructions for
the type of installation you have
Figure 8
If range will be installed with a cabinet on both
sides, draw a center line on the floor between the
cabinets (see figure 8). If back of range will not be
flush with the wall (the location of the outlet may not
allow the range to be positioned against the wall), draw
a line on the floor where the back edge of the range will
be. Now install anti-tip brackets (see "Anti-Tip Bracket
Installation, page 10).
If range will be installed with a cabinet on one side
only, move the range into final position. Draw a line on
the floor along the side of the range that is not against
the cabinet. If back of range will not be flush with
the wall (the location of the outlet may not allow the
range to be positioned against the wall), draw a line
(Models with Electric Ovens and Gas Cooktop)
10"
(25.4 cm)
W A L L
Center
Line of
Range
Center
Line of
Range
on the floor where the back edge of the range will be.
Now install anti-tip brackets (see "Anti-Tip Brackets
Installation", page 10).
If range will not be installed against a cabinet, move
range into final position. Mark on the floor along both
sides of the range. If back of range will not be flush
with the wall (the location of the outlet may not allow
the range to be positioned against the wall), draw a
line on the floor where the back edge of the range will
be. Now install anti-tip brackets (see "Anti-Tip Brackets
Installation", page 10).

Gas Supply Installation

When shipped from the factory, this unit is designed
to operate on 4" water column (1.0 kPa) Natural gas
manifold pressure. A convertible pressure regulator (see
figure 2) is connected to the range manifold and MUST
be connected in series with the gas supply line. To
access the regulator, remove the drawer.
For proper operation, the maximum inlet pressure
to the regulator should be no more than 14" of water
column pressure (3.5 kPa).
The inlet pressure to the regulator must be at least 1"
(.25 kPa) greater than the regulator manifold pressure
setting. The regulator is set for 4" water column (1.0
kPa) Natural gas manifold pressure; the inlet pressure
must be at least 5" water column (1.25 kPa) Natural
gas. For LP/Propane gas, the regulator must be set for
10" water column (2.5 kPa) manifold pressure; the inlet
pressure must be at least 11" water column (2.75 kPa).
The supply line should be equipped with an approved
shutoff valve (see Figure 9). This valve should be located
in the same room as the range and should be in a
location that allows ease of opening and closing. Do not
6
Figure 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fpdf4085kf - 40" dual fuel range

Table of Contents