Checking Environmental Conditions Of Oem Product; Printer Environmental Conditions; Relative Humidity; Ticket Environmental Conditions - TransAct ithaca 700 Series Maintenance Manual

Table of Contents

Advertisement

Model 750

Checking Environmental Conditions of OEM Product

The Model 750 is designed to be placed within any OEM product that has been designed
to support the weight of the printer (about 6 pounds or 2.7 kg). Be aware that the
environmental conditions of the location where you place the printer have an affect
on the it's performance and longevity.

Printer Environmental Conditions

The printer will run its best when stored and operated in an environment
that meets the following temperature and humidity conditions.
Operating:
Storage:
Shipping:

Relative Humidity

Operating:
Storage:
Shipping:
* Exposure to high or low temperatures for periods of greater
than 48 hours will lead to significantly reduced print head life.

Ticket Environmental Conditions

Activation Temperature
Initial
Effective
Optimum
Image
Development
Ticket type
Page 8
Series 700 Maintenance Manual
0° to 40°C/32° to 113° F
-20° C to 70° C *
-40° to 70°C *
5% to 90% (non-condensing)
10% to 90% (non-condensing)
95% (non-condensing)
74 ± 5° C
83 ± 5° C
90 ± 5° C
Black
1.35/1.60 (ATLANTEK 0.5 ms)
1.10/1.40 (ATLANTEK 0.35 ms)
Kanzaki TO-381N or approved equivalent
Ithaca Ticket Part Number 100-02108
Rev H