X-Radiation
Warning:
1.
The potential sources of X-Radiation in TV sets are the
High Voltage section and the picture tube.
2.
When using a picture tube test jig for service, ensure
that jig is capable of handling
Radiation.
Note:
It is important to use an accurate periodically cali-
brated high voltage meter.
1.
Set the brightness to minimum.
2.
Measure the High Voltage. The meter reading should
31.5 (+1.5, -1.5) kV
indicate
out of tolerance, immediate service and correction is
required to prevent the possibility of premature compo-
nent failure.
3.
To prevent an X-Radiation possibility, it is essential to
use the specified picture tube.
33.0kV
without causing X-
. If the meter indication is
- 4 -