Models H18PA and VSB18PA
• Rating (Variable): 16,000/23,000 Btu/Hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 14" W.C., Minimum 11"* W.C.
• Shipping Weight: 27 lbs.
Models H18NA and VSB18NA
• Rating (Variable): 17,000/24,000 Btu/Hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 10.5" W.C., Minimum 5"* W.C.
• Shipping Weight: 27 lbs.
*For the purpose of input adjustment.

TECHNICAL SERVICE

You may have further questions about installa-
tion, operation or troubleshooting. If so, contact
DESA Heating, LLC at 1-866-672-6040. When
calling please have your model and serial
numbers of your heater ready.
You can also visit DESA Heating, LLC's web
site at www.desatech.com.
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If
they can't supply original replacement part(s),
call DESA Heating, LLC at 1-866-672-6040.
When calling DESA Heating, LLC, have
ready:
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural
gas)
• purchase date
24

SPECIFICATIONS

REPLACEMENT PARTS

www.desatech.com
Models H24PA and VSB24PA
• Rating (Variable): 16,000/26,000 Btu/Hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 14" W.C., Minimum 11"* W.C.
• Shipping Weight: 27 lbs.
Models H24NA and and VSB24NA
• Rating (Variable): 17,000/26,000 Btu/Hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 10.5" W.C., Minimum 5"* W.C.
• Shipping Weight: 27 lbs.
*For the purpose of input adjustment.

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If
so, contact your local natural or propane/LP
gas supplier.
Usually, we will ask you to return the part to
the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product.
If they can't supply original replacement
part(s), contact your nearest Parts Central
(see page 25) or call DESA Heating, LLC at
1-866-672-6040 for referral information. A list
of authorized dealers can be found by visiting
www.deaint.com.
When calling DESA Heating, LLC, have
ready
• model number of your heater
• the replacement part number