Argox AS8520 Manual page 93

Hide thumbs Also See for AS8520:
Table of Contents

Advertisement

Code-128
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 55
Insertion group number selection of UPCA.
Format: The Code-128 can be translated to UCC/EAN-128
format if it starts with FNC1 character. The first FNC1 will
be translated to "]C1",and next to be a field separator code
as <GS>(1D
16
]C1
Data
Append / FNC4 control: When Append function is enabled,
it won't show the data immediately if imager read the barcode
includes FNC2 code. It will show all data until it read the
barcode, which doesn't have FNC2 code. When FNC4 is
enabled, the imager will send the data with FNC4 code. If the
FNC4 is ignore, the imager will send the data without FNC4
code.
Option Bar Code
Max. code length
Min. code length
).
<GS> Data
Program
Checksum
Option
00-64
00-64
87
th
Alphanumeric
Entry
00-64
*
00
00-64
*
00