Vanguard Firewerks VFRMV18NB Owner's Operation And Installation Manual page 23

Unvented (vent free) gas log heater
Table of Contents

Advertisement

OBSERVED PROBLEM
ODS/pilot lights but flame
goes out when control knob
is released
Burner does not light after
ODS/pilot is lit
Delayed ignition of burner
Burner backfiring during com-
bustion
116412-01E
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Control knob not fully
pressed in
2. Control knob not pressed in
long enough
3. Safety interlock system has
been triggered
4. Equipment shutoff valve not
fully open
5. Pilot flame not touching
thermocouple, which allows
thermocouple to cool, caus-
ing pilot flame to go out. This
problem could be caused by
one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
6. Thermocouple connection
loose at control valve
7. Thermocouple damaged
8. Control valve damaged
1. Inlet gas pressure is too
low
2. Burner orifice(s) clogged
3. Mislocated crossover tube
4. Remote selector in OFF
position
5. Wire disconnected from
gas control
1. Manifold pressure is too
low
2. Burner orifice(s) clogged
1. Burner orifice is clogged or
damaged
2. Damaged burner
3. Gas regulator defective
www.desatech.com
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep
control knob pressed in 30
seconds
3. Wait one minute for safety
interlock system to reset.
Repeat ignition operation
4. Fully open equipment shut-
off valve
5. A) Contact local natural or
propane/LP gas company
B) Clean ODS/pilot (see
Cleaning and Maintenance,
page 21) or replace ODS/
pilot assembly
6. Hand tighten until snug,
then tighten 1/4 turn more
7. Replace pilot assembly
8. Replace control valve
1. Contact local natural or
propane/LP gas company
2. C l e a n b u r n e r ( s ) ( s e e
Cleaning and Maintenance,
page 21) or replace burner
orifice(s)
3. Contact qualified service
person
4. Put remote selector in ON
position
5. S e e Wi r i n g D i a g r a m ,
page 20
1. Contact local natural or
propane/LP gas company
2. C l e a n b u r n e r ( s ) ( s e e
Cleaning and Maintenance,
page 21) or replace burner
orifice(s)
1. Clean burner (see Cleaning
and Maintenance, page 21)
or replace burner orifice
2. Replace damaged burner
3. Replace gas regulator
23