Check Your Package Thank you for purchasing the CONTEC product. The product consists of the items listed below. Check, with the following list, that your package is complete. If you discover damaged or missing items, contact your retailer. Product Configuration List - Product [COM-4PDHN-USB] …1...
No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO., LTD. CONTEC CO., LTD. makes no commitment to update or keep current the information contained in this document. The information in this document is subject to change without notice.
Table of Contents Check Your Package ............................ i Copyright ..............................ii Trademarks ..............................ii Table of Contents ............................iii BEFORE USING THE PRODUCT About the Product ............................1 Features ..............................1 Support Software ..........................2 Accessories (Option) ..........................2 Customer Support ............................3 Web Site ..............................
Page 5
If Setup fails to be performed normally ....................20 INSTALLATION AND CONNECTING WITH EXTERNAL DEVICES Installation Method ............................ 21 Mounting on a DIN Rail ........................21 Desktop Installation ........................... 23 Wall Installation ..........................23 Installation Using the Magnet ......................24 Steel wall installation .........................
1. Before Using the Product 1. Before Using the Product This chapter provides information you should know before using the product. About the Product This product is an USB2.0-compliant product designed for extending RS-422A/485 compatible serial communication functionality on your PC. This product supports a baud rate of up to 921,600bps and has separate 128-byte / 384-byte buffer memory for transmit and receive.
Supports the communication class of .NET Framework (SerialPort class). For more details on the supported OS, applicable language and new information, please visit the CONTEC’s Web site. Accessories (Option) AC adaptor (Input : 90 - 264VAC, output : 12VDC 1.0A)
You can download updated driver software and differential files as well as sample programs available in several languages. Note! For product information Contact your retailer if you have any technical question about a CONTEC product or need its price, delivery time, or estimate information. Limited One-Year Warranty CONTEC products are warranted by CONTEC CO., LTD.
Even when using this product continuously, be sure to read the manual and understand the contents. Do not modify this product. CONTEC will bear no responsibility for any problems, etc., resulting from modifying this product. Regardless of the foregoing statements, CONTEC is not liable for any damages whatsoever (including damages for loss of business profits) arising out of the use or inability to use this CONTEC product or the information contained herein.
Page 10
1. Before Using the Product Regarding “CE EMC Directive Class A Notice” The ferrite core must be installed in interface connecting cable so that this product may suit the above-mentioned standard. Name Maker Turn Quantity Installation Site on USB cable at product KRFC-6 KRFC-9 on FG cable at product...
1. Before Using the Product Environment Use this product in the following environment. If used in an unauthorized environment, this product may overheat, malfunction, or cause a failure. Operating temperature -20 - 60°C Humidity 10 - 90%RH (No condensation) Corrosive gases None Floating dust particles Not to be excessive...
2. Setup 2. Setup This chapter explains how to set up this product. What is Setup? Setup means a series of steps to take before the product can be used. Different steps are required for software and hardware. Installing the driver This section enables you to prepare the software and hardware by following each step in this chapter with the bundled disk “COM Setup Disk”.
2. Setup Step 1 Installing the Software Install software. Run [\USB\COM-4CN-USB\Setup.exe] from the bundled disk. (1) The screens below show the installation.Click [next]. (2) Accept the license agreement, then click [Next>]. (3) The setup is completed. COM-4PDHN-USB...
2. Setup Step 2 Installing the Hardware When using the product in the Windows environment, the OS needs to recognize the peripheral devices. This is called hardware installation. If you are using more than one product, be sure to complete the first installation, then install the next one.
2. Setup Component Functions LED indicator Meaning Status POWER (Green) Power status OFF: Power has not been supplied. ON: Power has been supplied. RxD (Yellow) Reception status Output status indication OFF : Data has not been received by the RS-422A/485 ON : When receiving data by the RS-422A/485 TxD (Green) Transmission status...
2. Setup Setting of Terminator The terminator setting switch controls whether or not a terminator is inserted into each signal line. Set the terminators on or off in accordance with the devices with which you are communicating. The terminators on the product are 100Ω resistors. Setting Procedure If you wish to use a terminator of other than 100Ω, set the bit 1 and 2 of corresponded channels OFF, and insert an external terminator.
Page 17
2. Setup - Full -duplex Terminator (Bit 9) Terminator (Bit 7) Inserted Not inserted TERM MODE TERM MODE SW1 - 4 SW1 - 4 Terminator (Bit 7) Terminator (Bit 9) Figure 2.3. Example Connection Oneself loop to RTS and CTS in Full Duplex The figure below shows the circuit associated with the data transfer mode setting switch and terminator setting switch.
2. Setup How to supply power to the product Connect to the external power using the power input connector of this product (suitable cable is AWG28 - 16). Even when using the commercial DC output power supply, follow the instruction described here. 12-24VDC - Connector used MC1,5/3-G3,5 [PHOENIX CONTACT]...
2. Setup Connecting the Product (1) Power on the PC first before connecting the product. Then, power on the product. The power LEDs light up when both the external power supply and the USB cable are connected. Only with one of them connected, the lights will not be on. Figure 2.6.
Page 20
2. Setup (3) Sandwich the supplied USB cable with the USB cable attachment and connect to the product. This makes the cable hard to disconnect. Figure 2.8. Connecting the Product CAUTION The USB cable attachment cannot be used excluding an attached cable. When the USB cable attachment is being used, do not perform removing and connecting the USB cable on the product side repeatedly.
2. Setup Setting with the Found New Hardware Wizard Depending on the OS that you use, the installation process may start automatically without starting the wizard. In this situation, proceed to "Step 3 Initializing the Software" section at the end of this chapter. Performing installations on various operating systems Help files containing the methods to follow in performing installations on different Windows operating systems are included on the bundled disk, so refer to the files in the following folder.
2. Setup Step 3 Initializing the Software Assign COM ports. Also, COM port number that is previously assigned can be changed to a different number. (1) Start the [Device Manager]. * The name of the connected product will be displayed. COM-4PDHN-USB (2) Check that the new COM ports are displayed in the [Ports] folder.
2. Setup Step 4 Operation check Use the diagnosis program to check that the product and driver software work normally, thereby you can confirm that they have been set up correctly. Check Method If a cross cable is not available, you can test communication using a single COM port by means of loopback arranged by setting the switch on the connection cable box.
2. Setup Using the Diagnostic Program for Serial Communications Port Starting the Diagnostic Program for Serial Communications Port When 32bit Windows OS is used, Run\Utility\CommChk\i386\CommChk.exe from the bundled disk. When 64bit Windows OS is used, Run\Utility\CommChk\amd64\CommChk.exe from the bundled disk. Communication Settings COM Setup: Specify the number of the COM port you wish to test.
2. Setup Start test Click the [Start] button to start the test using the specified conditions. View test result The test result is displayed in the [Message] window. A successful completion message appears if the test completed OK. If Setup fails to be performed normally Contact your retailer.
3. Installation and connecting with external devices 3. Installation and connecting with external devices Installation Method Mounting on a DIN Rail How to mount (1) Pull down the fixed hooks with a slotted screwdriver to unlock. Figure 3.1. Mounting on a DIN Rail < 1 / 3 > (2) Hook the product on the upper part of the DIN rail, and press it to the lower part of to the DIN rail.
Page 27
3. Installation and connecting with external devices How to remove (1) Pull down the fixed hooks with a slotted screwdriver to unlock. Figure 3.2. Removing the product from the DIN rail < 1 / 3 > (2) With the hooks unlocked, pull the lower part of this product toward you. Figure 3.2.
3. Installation and connecting with external devices Desktop Installation Using the rubber feet When required to mount the product on the desktop, mount it on a horizontal platform. The rubber feet can be mounted in their mounting holes as shown in the following figure. Figure 3.3.
3. Installation and connecting with external devices Installation Using the Magnet Attaching a magnet makes it easy to mount or remove the product on or from a metal surface such as steel desk or partition. The commercial magnet can be purchased individually. CAUTION Do not let the magnet go near objects that can be affected by magnetic fields.
3. Installation and connecting with external devices Steel wall installation Mount the product directly on the steel wall. Pull it gently after mounting to confirm that it will not drop off from the wall. Figure 3.7. Steel wall installation COM-4PDHN-USB...
3. Installation and connecting with external devices Installation Conditions Installation orientation It is possible to mount it in the orientations shown in the following figures. Other orientations would cause problems in usage, such as inadequate heat dissipation. DIN rail fixation Vertical installation Horizontal installation Installation on a ceiling...
Page 32
3. Installation and connecting with external devices Spacing between the system product and any surrounding objects Secure a distance of at least 50mm between the top of the main product (single use) and any surrounding objects. Do not locate the product in a fully enclosed housing. 50mm 50mm or more...
3. Installation and connecting with external devices Connection Method Interface Connector Use the interface connectors of the product to connect with external devices. - Connector used MC 1,5/5-G-3,5 equivalent [PHOENIX CONTACT] - Applicable connectors MC 1,5/5-ST-3,5 equivalent [PHOENIX CONTACT] - Applicable wire AWG28-16 Figure 3.11.
3. Installation and connecting with external devices Types of Cable and Example Connections The figures below show examples of how to connect the cable for the product. The RS-422A/485 interface works based on a differential signal whereby the signal is carried by the potential difference between two lines (+ and -).
Page 35
3. Installation and connecting with external devices COM-4PDHN-USB...
4. Function 4. Function This section describes the features of this product. Communication Function Serial Data Transmission Sends and receives data in accordance with the RS-422A/485 standard. The baud rate for each channel can be set independently in the range 300 to 921,600bps by software. Send and Receive Data Buffers Each channel has a separate 128-byte send and 384-byte receive buffer.
4. Function Setting the Baud Rate The output baud rate can be set by setting the software. Baud rate: 300 - 921,600 bps However, when the result contains a fractional part in the calculation of the division register listed below, since the division register value is rounded down to the nearest integer,a setting error of the baud rate occurs.
5. About Software 5. About Software About standard COM driver software The following functions can be realized with the bundled disk "COM Setup Disk". Operation under Windows and Linux. The serial ports can be used in the same way as the standard COM ports on the PC. The products can be used for all types of serial communications such as for remote access service (RAS) and uninterruptible power supply (UPS) applications.
6. About Hardware 6. About Hardware This chapter provides hardware specifications and hardware-related supplementary information. Hardware specification Table 6.1. Specifications Item Specifications Number of channels Interface type RS-422A/RS-485 Transfer method Asynchronous serial transfer Baud rate 300 - 921,600bps *1 *2 7, 8 bits Data length 1, 2 stop bits *1...
Page 41
6. About Hardware Communication cable: 28AWG, double shielded cable, twisted pairs used for each +/- signal line. The table below lists the maximum communication distances of the terminator resistor value and individual cable diameters. The terminators on the product (100Ω) and the terminators generally used with RS-422A/485(120Ω) are listed. Maximum communication distances of the terminator resistor value (100Ω) and cable diameter Maximum Communication...
Page 42
125VAC 7A attached AC cable The current consumption (Max.) of the F&eIT N series supported by this product is 6.5W. When the short interruption occurs and the defective operation of the equipment is generated, please insert the power supply of the equipment after pulling out it.
6. About Hardware Physical dimensions USB I/O Terminal COM-4PDHN-USB Isolated R S-422A/485 4ch I/O Unit (154) [mm] Figure 6.1. Physical dimensions 75±1 +12V N.C. 1500±100 [mm] +200 1830 Figure 6.2. AC adapter (POA201-10-2) Physical dimensions COM-4PDHN-USB...
Page 45
CONTEC CO., LTD. September 2018 Edition 3-9-31, Himesato, Nishiyodogawa-ku, Osaka 555-0025, Japan https://www.contec.com/ No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO., LTD. [09282018] [11302017] Management No. NA05918 [09282018_rev3] Parts No.