7. Reference Sheet

7-1 Refrigerating Cycle Diagram

Indoor Unit
■ CONDENSER
High temperature and high pressure gas state coolant discharged from the compressor is converted to a liquid state as it
is cooled down by the heat emission in the outdoor condenser unit, and sent to the evaporator.
■ COMPRESSOR
Low temperature and low pressure coolant is compressed and sent to the cycling system.
■EVAPORATOR
Liquid coolant sucked in through the capillary tubes cools down the room by absorbing the surrounding
heat as it evaporates (converting from liquid to gas). (Absorbing heat required for evaporation)
■SERVICE VALVE
You can open the valve by turning the need valve counterclockwise using hex wrench, and it is used for vacuum, gas
purging, coolant injection, coolant purging, and indoor-outdoor unit connection.
■ACCUMULATOR
Accumulator prevents the flow of liquid-state coolant into the compressor. (Liquid-state coolant flowing into the compres-
sor will overload the compressor.)