• Forced thermostat off function
Rotary SW on External
input and output PCB
2
B
C
8-4. Details of function
External input
External input and output PCB
On
Input
Off
On
Compressor
Off
Room temp.
Set temp.
- 27 -
Input signal
Off → On
CN313
On → Off
Command
Thermostat off
Normal operation