Russound Sphere E Series Installation Manual page 11

8.4” color touchscreen
Hide thumbs Also See for Sphere E Series:
Table of Contents

Advertisement

Connections
Note: Before making any connections, make sure the multiroom system is
powered off.
Important: For each CAT-5e cable, crimp an RJ-45 connector on each end of
the cable, following the T568A standard. The total length of the control CAT-5e
cable(s) between the TSV-E5 and the router can not exceed 250' (76.2m)
RJ-45 Using T568A
Wiring Standard
CAT-5e cable -- TSV to PoE power supply
Connect one end of the cable to the Ethernet/Power jack on the TSV-E5. (If
using a wall plate for a desktop or VESA installation, use a single pre-terminated
stranded CAT-5e cable between the TSV-E5 and the wall plate.) Plug the other
end of the cable into the PoE power supply's DATA/PWR jack. At the TSV-E5
end of the cable, snap the included ferrite bead around the cable 2" (5 cm) from
the connector as shown in the instructions on page 12.
CAT-5e cable -- PoE to router
Connect one end of a CAT-5e cable to the DATA jack on the PoE power
supply, and the other end to an available port on the router.
CAT-5e cable -- Router to ACA-E5
Connect one end of a CAT-5e cable from an available port on the router, and
the other end to the Ethernet port of the controller. Cable should not exceed
250' (76.2m). The master ACA-E5 must be connected to the same router that
the PoE power supply is connected.
Note: In a multi-controller setting, there should only be one master ACA-E5
in the installation.
CAT-5e cable -- IR pass-through
If using an IR pass-through CAT-5e (or CAT-5) cable, plug it into the zone
keypad jack on the system controller corresponding to the zone in which the
TSV-E5 is located. Cable should not exceed 250' (76.2m). If there is also a
keypad plugged into that zone on the controller, an SA-ZX3 splitter must be
used.
IR Signal cable
To connect a remote IR receiver, connect the signal cable wires to the screw
terminals on the IR receiver connector as shown. Use one twisted pair for voltage
and ground, and the other twisted pair for IR signal and status. After connecting
the wires, plug the connector into the socket on the rear of the TSV-E5.
Connect the other end of the signal cable to the leads or terminals of the
IR receiver according to its installation instructions. Leave the cable shield
disconnected at the IR receiver.
Note: When using an external IR receiver, you should disable the touch-
screen's internal IR receiver to avoid conflicting signals. Select the Enable/
Disable IR screen in Installer Options accessible from the System Screen, then
press 'Disable'. A confirmation message will appear.
Power cord (PoE Power Supply)
Plug one end of the power cord into the IEC receptacle on the PoE power
supply and the other end into an AC wall receptacle, surge protector, or power
conditioner.
Russound TSV-E5
Installation
WHITE
GREEN
BLACK + SHIELD
RED
Manual
INSTALLATION
11

Advertisement