Download Print this page
ADTRAN 424 ONT Quick Start

ADTRAN 424 ONT Quick Start

2 pots/ 4 gige

Advertisement

Quick Links

Quick Start
D
ESCRIPTION
This Quick Start supports the 424 2 POTS/ 4 GigE Optical
Network Terminal (424 ONT). The illustration above displays the
rear of the 424 ONT and a cut-away of the top depicting status
LEDs.
This document describes the part numbers listed in the table
below.
Description
424 2 POTS/ 4 GigE with NA power adapter
(included)
424 2 POTS/ 4 GigE with AU power adapter
(included)
F
EATURES
The 424 ONTs have the following features:
Two POTS Ports
Four Gigabit Ethernet Ports
12 VDC Power Plug
UPS Connector
Reset Button
Fiber Connector
Resetting the ONT
A reset button is available if the 424 ONT needs to be rebooted.
To reset the 424 ONT, press the RESET button for 5 seconds or
longer.
f
WARNING!
All settings will return to Factory Defaults: Registration
provisioning will be lost.
424 ONT
2 POTS/ 4 GigE
1
2
3
4
12V
UPS
PHONE 2
PHONE 1
P/N
1287835F1
1287835F4
1
2
RESET
GE 1
GE 2
GE 3
GE 4
Voice Processing
Plain Old Telephone Service (POTS) uses in-band signaling tones
and currents to determine call status (for example, call request).
Because POTS allows for the transfer of audio signals below 3.3
kHz, POTS systems are also used for modems that allow data
transmission (referred to as dial up connections).
Ethernet Interface
The 424 ONT supports data service through four 10/100/
1000Base-T Ethernet interfaces via RJ-45-style connectors.
Power
Power is provided by a 12 VDC Power Adapter that is included
with the 424 ONT. The Power Adapter operates from a main
power source input of 100 to 240 VAC, 50/60 Hz, with a nominal
output of 12 VDC. The total power consumption with 4 Ethernet
Ports running and both POTS lines off-hook is approximately 15.0
Watts. A connection for an optional un-interruptible power supply
(UPS) is also provided.
UPS
The 424 ONT provides an optional connection for an
Uninterruptible Power Source (UPS). A UPS is a battery backup
system designed to continue providing power when the primary
power source is lost. Power is supplied to the 424 ONT by a local
power source with battery backup that utilizes the AC power at the
customer premises and keeps the battery charged.
I
NSTALLATION
After unpacking the 424 ONT, inspect it for damage. If damage is
noted, file a claim with the carrier and then contact ADTRAN. For
more information, refer to the warranty.
Installation consists of positioning the 424 ONT either on a
desktop or wall mount, connecting POTS, Ethernet, and power.
December 2019
61287835F1-13A

Advertisement

loading

Summary of Contents for ADTRAN 424 ONT

  • Page 1 ■ Reset Button power source is lost. Power is supplied to the 424 ONT by a local ■ Fiber Connector power source with battery backup that utilizes the AC power at the customer premises and keeps the battery charged.
  • Page 2 Required tools Figure 1. Wall Mount Installation Standard technician tools and those listed below are required for 2. Use the keyholes on the rear of the 424 ONT as a template installing the 424 ONT: and mark the wall accordingly.
  • Page 3 The 424 ONT can typically use an un-interruptible power supply computers will be connected to the GE2 through GE4. (UPS) if desired. Power is supplied to the 424 ONT by a local power source with battery backup that utilizes the AC power at the Step 4: Clean Fiber Optics Cable Connections customer premises.
  • Page 4 For inquiries, go to: http://adtran.com/training Warranty: ADTRAN will replace or repair this product within the warranty period if it does not ADTRAN CUSTOMER CARE: meet its published specifications or fails while in service. Warranty information can be From within the U.S.