ORF-200 REGULATE RECTIFIER
Installation
・Provide enough anti-vibration measures to mount it in an aircraft.
・Determine the position of the regulate rectifier, well ventilated, not to be exposed to radiation heat and
engine exhaust gas.
・Use four M4 screws when it is mounted.
・Connect three white input cables of ORF-200 to three output cables of the generator. There is no
polarity on each three cables.
・Output cables (RED DC +, BLACK DC -) do not have connectors. Prepare connectors that fit to your
equipment by yourself.
CAUTION:
・Do not exceed the rated output values. The regulate rectifier can be overheated under high
atmospheric temperature even it is used within the rated values. So position it in a well-ventilated
place.
・When output of ORF-200 is connected to your equipment, put a 15A – 20A fuse in the RED cable
(DC +).
Adjustment method of output voltage
・Output voltage is adjustable between 6V to 28V.
《How to reset the output voltage》
① Remove the four screws on bottom of ORF-200, and take out the lid.
② Reset the voltage by turning the trimmer shown in the picture. You can increase the voltage by turning
it clockwise. Adjust the output voltage with no load without connecting output cable to any equipment
inputting double or more voltage than the output voltage you set. The input voltage does not have to be
3-phase AC when you adjust the output voltage. You can use single-phase AC or even DC. Use two of the
three input cables randomly selected when you use single-phase AC or DC for input.
③ Attach the lid with the four screws (tightening torque 0.5N-m). Do not attach the lid reverse since the
lid is asymmetric with a cutout for cables.
Installation
1
Voltage adjusting volume
Turn clockwise to increase
the voltage
5