Download Print this page

Advertisement

Quick Links

100W Generator for UAV
OGA-100 KIT
for GF40U-FI
INSTRUCTION MANUAL
version 2.41E
2021.08.01
O.S. ENGINES MFG. CO., LTD.

Advertisement

loading

Summary of Contents for O.S. engine OGA-100 KIT

  • Page 1 100W Generator for UAV OGA-100 KIT for GF40U-FI INSTRUCTION MANUAL version 2.41E 2021.08.01 O.S. ENGINES MFG. CO., LTD.
  • Page 2: About The Product

    ABOUT THE PRODUCT ・This is OGA-100 generator kit to be mounted on GF40U-FI. The kit contains OGA-100 generator with a mount, a drive belt, a drive pulley, ORF-200 regulate rectifier. ・OGA-100 in the kit also has a stay, which supports rear part of the generator. It is an extra part included in the kit to mount on GF40U-FI.
  • Page 3: Names Of The Parts

    NAMES OF THE PARTS 1. OGA-100A Generator 2. ORF-200 Regulate rectifier 3. Belt 4. Driven pulley 5. Generator adaptor(F) 6. Generator support(F) 7. Generator adaptor(R) 8. Generator support(R)
  • Page 4 Installation OGA-100A GENERATOR Lower Right side left side ・The position of the generator (OGA-100A) is choosable from the three positions shown above. ・Mount the Generator after mounting the engine. Use four screw holes for each depending on the mounting position. M4x25 Bolt M4x30 Bolt 15mm Spacer...
  • Page 5 Installation 1.Remove the pair of front bolts (M4 x 15) on the generator mount, where you intend to fit the Generator. There bolts are unnecessary in case the Generator is fit. 2. Bolt the Generator support (R) to Mounting plate(F) together with 15mm Spacers using M4x25 Bolts.
  • Page 6 Installation ORF-200 REGULATE RECTIFIER Installation ・Provide enough anti-vibration measures to mount it in an aircraft. ・Determine the position of the regulate rectifier, well ventilated, not to be exposed to radiation heat and engine exhaust gas. ・Use four M4 screws when it is mounted. ・Connect three white input cables of ORF-200 to three output cables of the generator.
  • Page 7 Parts list ■PARTS LIST / OGA-100 KIT for GF40U-FI Code No. Description 54062000 OGA-100 KIT FOR GF40U-FI 51040120 OGA-100A GENERATOR 54059001 GENERATOR ADAPTOR (F) 4A632000 BEARING 54059002 GENERATOR ADAPTER (R) OGA-100A 4AD50012 GENERATOR SUPPORT 100W (F) GF40U 4AD50016 GENERATOR SPACER 4.5 (2pcs.)
  • Page 8 Parts list...
  • Page 9 Installation ■SPECIFICATION (OGA-100A) Weit: 205 g Lead wire length: 100 mm Female connector: φ3.5 mm Induced voltage Ke: 1.053 mV/rpm Rated voltage: 12V @11400rpm Rated current: Maximum current: Maximum output: 100W(12V)/30minutes (the value in atmospheric temperature 20℃) 60W/continuous (the value in atmospheric temperature 20℃) Poles: Number of phases: Phase resistance:...
  • Page 10 Demantions ORF-200 Unit : mm OGA-100A (note 1.) (note 1.) Unit : mm note 1. Use the mounting screws whose length does not exceed the thickness of your bracket + 4mm, so that the length of screws which is screwed into the generator body is less than 4mm. If you screw into the screw body longer than 4mm, the screw will contacts the motor coil and will cause short circuit.
  • Page 11 MEMO...