Operation Of The Stove - USSC 1869 Owner’s Instruction And Operation Manual

Table of Contents

Advertisement

ASSEMBLY & INSTALLATION
CHIMNEY CAP MANDATORY
2 ft min
10 ft
11 ft min
PIPE
REDUCER
BAROMETRIC
DRAFT
REGULATOR
NON-COMBUSTIBL
E CONSTRUCTION
IN ACCORDANCE
WITH NFPA 211
FLOOR PROTECTOR
RULES FOR CONNECTOR PIPE
INSTALLATION
1.
The pipe should be firmly attached to the collar top
with 3 screws and sealed with stove cement.
2. Slope any horizontal pipe upward toward the chimney
at least 1/4" for each foot of horizontal run.
3. You must have at least 18" clearance between any
horizontal piping and the ceiling.
4. The pipe cannot extend into the chimney flue.
5. Seal each connector pipe joint with stove cement.
Also seal the pipe at the chimney.
6. Use 3 sheet metal screws at each joint to make the
piping rigid.
7. It is recommended that no more than two (2) 90
degree bends be used in the stove pipe installation as
more than two (2) may decrease the amount of draw
and possibly cause smoke spillage.
NOTE: The chimney connector shall not pass through an
attic, roof space, floor, ceiling, or similar concealed space.
Where passage through a wall or partition of combustible
construction is desired, the installation must conform
with NFPA 211.

OPERATION OF THE STOVE

1.
3 ft min
2. Burn coal only. Use wood for coal ignition purposes
3. After the fire has been started and is burning
4. Open/adjust spin draft on feed door to allow additional
5. Never build extremely large fires in this type stove as
PIPE
6. DO NOT touch the stove after firing
7. Never over fire this stove by building excessively hot
8. Inspect stove pipe every 90 days. Replace
9. This is a cast iron stove. It does not have welded
10. If stove begins to glow or turn red, you are over firing.
OVER FIRING THE APPLIANCE MAY CAUSE A
HOUSE FIRE. IF A UNIT OR CHIMNEY CONNECTOR
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN
FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR
FLAMMABLE LIQUIDS TO START OR "FRESHEN
USE COAL ONLY. DO NOT USE DRIED LUMBER,
TREATED WOOD ARTIFICIAL OR PRESSED LOGS.
NEVER STORE FLAMMABLE LIQUIDS, ESPECIALLY
GASOLINE. IN THE VICINITY OF THE HEATER.
7
Fully open slide draft on ash door and keep spin
damper on feed door closed.
only. Build six (6) small fires upon initial firing. Light
wood using paper, twigs, etc.
satisfactorily, close slide draft almost all the way.
air into the stove (on top of the fire). This will allow a
more efficient burn cycle.
damage to the stove or smoking may result.
fires as a house/building fire may result.
immediately if stove pipe is rusting or leaking smoke
into the room.
seams. From time to time you may have to "tune-
up" the stove by refilling and/or replacing the stove
cement or mortar along the seams.
CAUTION:
GLOWS, YOU ARE OVER FIRING.
CAUTION:
UP" A FIRE IN THE HEATER.
CAUTION:
WARNING:
© 2021 United States Stove Company

Advertisement

Table of Contents
loading

Table of Contents