Precautions For Safety - Toshiba RAV-RM301SDT-E Installation Manual

Hide thumbs Also See for RAV-RM301SDT-E:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
 Warning indications on the air conditioner unit
Warning indication
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect all remote
electric power supplies
before servicing.
WARNING
Moving parts.
Do not operate unit with grille
removed.
Stop the unit before the servicing.
CAUTION
High temperature parts.
You might get burned
when removing this panel.
CAUTION
Do not touch the aluminum
fins of the unit.
Doing so may result in injury.
CAUTION
BURST HAZARD
Open the service valves before
the operation, otherwise there
might be the burst.
5-EN
Description
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect all remote electric power supplies before servicing.
WARNING
Moving parts.
Do not operate unit with grille removed.
Stop the unit before the servicing.
CAUTION
High temperature parts.
You might get burned when removing this panel.
CAUTION
Do not touch the aluminium fins of the unit.
Doing so may result in injury.
CAUTION
BURST HAZARD
Open the service valves before the operation, otherwise there might be
the burst.
– 3 –
1

Precautions for safety

The manufacturer shall not assume any liability for the damage caused
by not observing the description of this manual.
WARNING
General
• Before starting to install the air conditioner, read through the
Installation Manual carefully, and follow its instructions to install the
air conditioner.
• Only a qualified installer or service person is allowed to do installation
work. Inappropriate installation may result in water leakage, electric
shock or fire.
• Do not use any refrigerant different from the one specified for
complement or replacement. Otherwise, abnormally high pressure
may be generated in the refrigeration cycle, which may result in a
failure or explosion of the product or an injury to your body.
• Before opening the intake grille of the indoor unit or service panel of
the outdoor unit, set the circuit breaker to the OFF position. Failure to
set the circuit breaker to the OFF position may result in electric
shocks through contact with the interior parts. Only a qualified
installer(*1) or qualified service person(*1) is allowed to remove the
intake grille of the indoor unit or service panel of the outdoor unit and
do the work required.
• Before carrying out the installation, maintenance, repair or removal
work, set the circuit breaker to the OFF position. Otherwise, electric
shocks may result.
• Place a "Work in progress" sign near the circuit breaker while the
installation, maintenance, repair or removal work is being carried out.
There is a danger of electric shocks if the circuit breaker is set to ON
by mistake.
• Only a qualified installer(*1) or qualified service person(*1) is allowed
to undertake work at heights using a stand of 50 cm or more or to
remove the intake grille of the indoor unit to undertake work.
• Wear protective gloves and safety work clothing during installation,
servicing and removal.
• Do not touch the aluminium fin of the unit. You may injure yourself if
you do so. If the fin must be touched for some reason, first put on
protective gloves and safety work clothing, and then proceed.
• Do not climb onto or place objects on top of the outdoor unit. You may
fall or the objects may fall off of the outdoor unit and result in injury.
6-EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rav-rm401sdt-eRav-rm561sdt-e

Table of Contents